RETRACTED: Influence of diameter and length on primary stability in various implant site densities—An in vitro study in polyurethane blocks
Pourquoi ce travail est-il dans la base ?
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.
Dossier post-publication
OpenAlex signale ce travail comme rétracté, mais aucune notice correspondante de Retraction Watch ne figure dans cette base.
Résumé
Abstract Background The influence of dental implant length and diameter on primary stability in various bone densities is not well understood. Aim To in vitro study the effect of length and diameter on resonance frequency analysis (RFA), insertion torque (IT) and displacement (DP) measurements of dental implants in different implant site densities. Materials and methods Dental implants of four different diameters (Ø 3.5, 4.0, 4.5 and 5.0 mm) and three different lengths (7, 11 and 15 mm) (Neoss Ltd, Harrogate, UK) were placed in polyurethane blocks of three different densities (Sawbones Europe AB, Malmö, Sweden). The primary stability was assessed by RFA (ISQ) (Osstell, Osstell AB, Gothenburg, Sweden) and insertion torque measurements (IT max in N cm) (iChiropo™, Bien‐Air Dental SA, Bienne, Switzerland). In addition, the blocks were mounted in a rig and a lateral force of 25 N cm was applied to the implants and the DP was measured in μm with a micrometer gauge placed on the opposite side of the load transducer. Statistical analyses using linear and quadratic models were applied. Results Implant length, diameter and block density were found to be significant independent predictors of RFA, IT max , and DP measurements. Implant length had a strong effect, while the effect of diameter in general was subtle, particularly in the softest block. Conclusions Implant length affects primary stability more than implant diameter in polyurethane blocks of uniform density along the whole length of the tested implants.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
La notice
- Revue
- Clinical Implant Dentistry and Related Research
- Thématique
- Dental Implant Techniques and Outcomes
- Domaine
- Dentistry
- Établissements canadiens
- —
- Organismes subventionnaires
- —
- Mots-clés
- PolyurethaneImplantPrimary (astronomy)DentistryIn vitroMaterials scienceBiomedical engineeringComposite materialMedicineChemistrySurgeryPhysics
- Résumé présent dans OpenAlex
- oui