MétaCan
Menu
Back to cohort

Cervical Spine Motion: A Fluoroscopic Comparison During Intubation with Lighted Stylet, GlideScope, and Macintosh Laryngoscope

2005· article· en· W1971588014 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueAnesthesia & Analgesia · 2005
Typearticle
Languageen
FieldMedicine
TopicAirway Management and Intubation Techniques
Canadian institutionsWestern University
Fundersnot available
KeywordsStyletLaryngoscopyIntubationMedicineCervical spineVideo laryngoscopeLaryngoscopesAnesthesiaSurgery

Abstract

fetched live from OpenAlex

In Brief The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope®, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight®. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope. IMPLICATIONS: The question of which is the optimum technique to intubate the trachea of a patient who may have a cervical(C)-spine injury remains unresolved. Using fluoroscopic video, C-spine motion during intubation was compared for Macintosh 3 blade, GlideScope, and Lightwand use. The Lightwand is associated with reduced C-spine movement during intubation compared to Macintosh laryngoscope.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.257
Threshold uncertainty score0.944

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.254
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it