MétaCan
Menu
Back to cohort
Record W1972449985 · doi:10.1088/0031-9155/58/7/2143

Study of light transport inside scintillation crystals for PET detectors

2013· article· en· W1972449985 on OpenAlexaff
Xin Yang, Evan Downie, Thomas J. Farrell, Hao Peng

Bibliographic record

VenuePhysics in Medicine and Biology · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsMcMaster University
Fundersnot available
KeywordsSilicon photomultiplierSpecular reflectionOpticsScintillatorScintillationPhotomultiplierReflector (photography)Materials scienceResolution (logic)Monte Carlo methodPhotonImage resolutionCrystal (programming language)Lyso-DetectorPhysicsComputer science

Abstract

fetched live from OpenAlex

Scintillation crystal design is a critical component in positron emission tomography system development, which impacts a number of performance parameters including energy resolution, time resolution and spatial resolution. Our work aims to develop a generalized simulation tool to model the light transport inside scintillation crystals with good accuracy, taking into account surface treatments, reflectors, temporal dependence of scintillation decay, and comprehensive experimental validations. The simulation has been validated against both direct analytical calculation and experimental measurements. In this work, the studies were performed for a lutetium-yttrium oxyorthosilicate crystal of 3×3×20 mm(3) dimension coupled to a Hamamatsu silicon photomultiplier, with respect to light output, rise-time slope, energy resolution and time resolution. Four crystal surface treatment and reflector configurations were investigated: GroundMetal, GroundPaint, PolishMetal and PolishPaint. The experiments were performed to validate the Monte Carlo simulation results. The results indicate that the best time resolution (0.96±0.05 ns) and good energy resolution (10.6±0.4%) could be produced by using a polished surface with specular reflector, while the configuration of a polished surface with diffusive reflector produces the best energy resolution (10.2±0.9%). The results indicate that a polished surface with diffusive reflector achieves the best energy resolution (10.2±0.9%) for 511 keV high energy photons, and a polished surface with specular reflector achieves the best time resolution (0.96±0.05 ns) measured against a Hamamatsu fast photomultiplier tube. The ground surface treatment is not recommended for its inferior performance in terms of energy and time resolution. Possible explanations and future improvements to be made to the developed simulation tool are discussed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.105
GPT teacher head0.347
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2013
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207