MétaCan
Menu
Back to cohort
Record W1974635620 · doi:10.1053/jars.2003.50032

The effect of suture anchor design and orientation on suture abrasion: An in vitro study

2003· article· en· W1974635620 on OpenAlexaff
Davide Bardana, Robert T. Burks, John R. West, Patrick E. Greis

Bibliographic record

VenueArthroscopy The Journal of Arthroscopic and Related Surgery · 2003
Typearticle
Languageen
FieldMedicine
TopicSurgical Sutures and Adhesives
Canadian institutionsKingston General Hospital
Fundersnot available
KeywordsFibrous jointAbrasion (mechanical)MedicineBiomechanicsSurgeryOrthodonticsMaterials scienceAnatomyComposite material

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the effects of suture anchor design and orientation on suture abrasion in a cyclic model. TYPE OF STUDY: In vitro. METHODS: Biomechanical studies have shown suture breakage to be a predominant mode of failure in a suture anchor repair construct. It is possible that suture abrasion during knot tying or in vivo cyclic loading may contribute to early failure. This study specifically investigates suture abrasion caused by 17 commonly used suture anchors and demonstrates the effects of suture anchor angulation and rotation on suture abrasion. To eliminate target tissue as a source of failure, all anchors were implanted into a solid block of sawbones material and tested with No. 2 Ethibond Excel sutures (Ethicon, Somerville, NJ). The testing model focused on 3 variables: suture anchor type, suture pull angle (SA) and angle of anchor rotation (RA). Abrasion testing was then performed on a servohydraulic materials testing system by continually cycling the suture back and forth through each anchor with an excursion of 4 cm at a rate of 0.5 Hz under a load of 10 N until suture failure occurred. RESULTS: Sutures performed significantly better when cycled in line with the anchor at 0 degrees SA with 0 degrees RA than they did at 45 degrees SA with 0 degrees RA or 45 degrees SA with 90 degrees RA. We found no significant difference between anchors tested at 45 degrees SA with 0 degrees RA and 45 degrees SA with 90 degrees RA. For tests performed using metallic suture anchors, all constructs failed by fraying of the suture. Constructs using biopolymer anchors and nonabsorbable polymeric anchors experienced a mixture of suture and anchor eyelet failures. CONCLUSIONS: In addition to the statistically significant detrimental effects of suture anchor angulation and rotation on suture abrasion, suture anchor eyelet design may also influence suture abrasion. Surgeons should be aware of the effects of anchor angulation, suture position in the eyelet, and design and composition of the eyelet to maximize the durability of the construct.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.278
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations97
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueArthroscopy The Journal of Arthroscopic and Related SurgerySame topicSurgical Sutures and AdhesivesFrench-language works237,207