MétaCan
Menu
Back to cohort
Record W1979664918 · doi:10.1097/brs.0b013e3181cbfd09

Clinical Accuracy of Computer-Assisted Two-Dimensional Fluoroscopy for the Percutaneous Placement of Lumbosacral Pedicle Screws

2010· article· en· W1979664918 on OpenAlexaff
Bheeshma Ravi, Ali Zahrai, Raja Rampersaud

Bibliographic record

VenueSpine · 2010
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsUniversity Health NetworkToronto Western HospitalUniversity of Toronto
Fundersnot available
KeywordsMedicineFluoroscopyPercutaneousLumbosacral jointPerforationSurgerySpinal fusionNuclear medicineRadiology

Abstract

fetched live from OpenAlex

STUDY DESIGN: Clinical case series. OBJECTIVE: The primary objective of this study was to evaluate the clinical accuracy of computer-assisted two-dimensional fluoroscopy (2D-CAS) for the percutaneous placement of lumbosacral pedicle screws. SUMMARY OF BACKGROUND DATA: Loss of visual anatomic landmarks and reduced tactile feedback increases the risk of pedicle screw misplacement by when using minimally invasive (MIS) percutaneous techniques. However, objective data on screw misplacement in this scenario is lacking. METHODS: A MIS-2D-CAS technique (FluoroNav) was used for the placement of pedicle screws in 41 consecutive patients undergoing MIS-interbody instrumented fusion. Postoperative computerized tomography (CT) was obtained in all patients at 6 months after surgery and was evaluated by 3 observers. The relative position of the screw to the pedicle was graded regarding pedicle breach (I, no breach; II, <2 mm; III, 2-4 mm; IV, >4 mm), breach direction, vertebral body perforation and screw trajectory. Interobserver reliability of CT grading was assessed with kappa statistics. RESULTS: A total of 161 screws were placed. No neurologic, vascular, or visceral injuries occurred. About 37 (23%) screws breached the pedicle. The majority (83.8%, 31/37) of breaches were graded II. There were 5 Grade III and 1 Grade IV breaches. Medial versus lateral breaches occurred in 30% (11/37) and 60% (22/37), respectively; 10% (4/37) of the breaches were superior. Overall, 8 (5%) vertebral body breaches occurred. Of the pedicle screws, 19 (12%) had trajectories that deviated from acceptable, with the majority being medial (16/19, 84%). Fluoroscopy time for screw placement was typically less than 20 seconds total per case. There was 1 clinically significant breach at L5 (III, medial) which resulted in a L5 radiculopathy. Kappa statistics showed excellent overall agreement between reviewers (k = 0.73-0.92; 90%-96% agreement). CONCLUSION: The two-dimensional (2D) virtual fluoroscopy is a clinically acceptable option for percutaneous placement of pedicle screws. However, this technique requires cautious application and is particularly vulnerable to axial trajectory errors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.032
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.032
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.393
Teacher spread0.359 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations120
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207