MétaCan
Menu
Back to cohort
Record W1993930940 · doi:10.1117/12.974786

A compact 2048x1536 pixel infrared imager for long distance surveillance

2012· article· en· W1993930940 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2012
Typearticle
Languageen
FieldEngineering
TopicInfrared Target Detection Methodologies
Canadian institutionsInstitut National d'Optique
Fundersnot available
KeywordsPixelDot pitchInfraredOpticsImage resolutionBolometerPhysicsWavelengthCardinal pointField of viewDetector

Abstract

fetched live from OpenAlex

The evolution of infrared imaging technology has always followed, from a distance, the evolution of the technology in the visible waveband with ever increasing resolutions and decreasing pixel pitch. With such evolution the cameras in the visible are smaller than ever and display high quality imaging. Nowadays the size of the pixels in the infrared is generally much larger than its counterpart in the visible. However, the ratio of the size of the pixel to the wavelength is much smaller in the infrared than in the visible with the consequence that the gain on the pixel size could be limited considering today's rules of design. In the infrared, the recent advent of large 1024 x 768 pixel focal plane arrays based on 17 um pixel for the 8 to 12 um waveband raises development challenges. Nevertheless, it was recently shown that sampling a scene at a frequency higher than the one corresponding to the pixel pitch is an efficient way of increasing the resolution of an image for given pixel size and FPA dimensions. Following this strategy a 2048 x 1536 pixel imager with integrated microscan was developed based on an uncooled bolometer FPA. Due to its very small 8.5 um efficient pixel pitch the imager offers very high resolution and large field-of-view (FOV) using a short 50 mm focal length. Furthermore, since the size of the FPA is maintained at a reasonable size and the pixel pitch is very small the optics is compact and lightweight and the level of aberrations at the larger angles of the FOV is kept to a minimum offering excellent imaging quality. Such a platform could thus be used for very compact surveillance system and remote sensing instrumentation. This paper reviews the optics developed to perform the microscanned acquisition, the acquisition electronics and presents examples of high-resolution imaging. Finally, comparison of imaging with and without microscan is provided illustrating the usefulness of the microscan system despite the fact that the efficient pixel pitch is very close to the lower limit of the 8 to 12 um infrared waveband.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.477
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.254
Teacher spread0.234 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it