MétaCan
Menu
← all works

Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis

2013· review· en· 228 citations· W2098933452 on OpenAlex· 10.1503/cmaj.130952

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.
Canadian funderA Canadian agency funded it. The work may carry no Canadian affiliation at all.
Canadian venueIt was published in a Canadian venue.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
Metaresearch, Meta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Meta-analysisConsensus signal: none
Genre
Candidate signal: ReviewConsensus signal: Review
Teacher disagreement score
0.518
Threshold uncertainty score
1.000
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.081
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0100.004
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.131
GPT teacher head0.380
Teacher spread
0.250 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

BACKGROUND: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. METHODS: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. RESULTS: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea-hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. INTERPRETATION: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Canadian Medical Association Journal
Topic
Obstructive Sleep Apnea Research
Field
Medicine
Canadian institutions
University of Alberta
Funders
National Institute for Health and Care ResearchUniversity of Alberta
Keywords
MedicinePolysomnographyObstructive sleep apneaMeta-analysisReceiver operating characteristicSleep apneaPopulationApnea–hypopnea indexSleep studyDiagnostic accuracyHypopneaLogistic regressionPhysical therapyApneaInternal medicine
Has abstract in OpenAlex
yes