MétaCan
Menu
Back to cohort
Record W2113699947 · doi:10.1086/501999

Prospective Surveillance for Primary Bloodstream Infections Occurring in Canadian Hemodialysis Units

2002· article· en· W2113699947 on OpenAlexaffabout
Geoffrey Taylor, Denise Gravel, Lynn Johnston, John M. Embil, Donna Holton, Shirley Paton

Bibliographic record

VenueInfection Control and Hospital Epidemiology · 2002
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsUniversity of ManitobaDalhousie UniversityHealth CanadaUniversity of Alberta
Fundersnot available
KeywordsHemodialysisMedicineDialysisBloodstream infectionProspective cohort studyIncidence (geometry)Vascular accessCentral venous catheterBacteremiaHome hemodialysisIntensive care medicineEmergency medicineCatheterInternal medicineSurgeryAntibiotics

Abstract

fetched live from OpenAlex

OBJECTIVE: Bloodstream infections are a major cause of morbidity and mortality in patients receiving long-term hemodialysis. We wanted to determine the incidence of hemodialysis-related bloodstream infections in Canadian centers participating in the Canadian Nosocomial Infection Surveillance Program. METHODS: Prospective surveillance for hemodialysis-related bloodstream infections was performed in 11 centers during a 6-month period. Bloodstream infections were defined by published criteria. Hemodialysis denominators included the number of dialysis procedures, the number of patient-days on dialysis, and the frequencies of different types of vascular access. RESULTS: There were 184 bloodstream infections in 133,158 dialysis procedures (1.4 per 1,000) and 316,953 patient-days (0.6 per 1,000). Hemodialysis access through arteriovenous (AV) fistulae was associated with the lowest risk for bloodstream infection (0.2 per 1,000 dialysis procedures). The relative risk for infection was 2.5 with AV graft access, 15.5 with cuffed and tunneled central venous catheter (CVC) access, and 22.5 with uncuffed CVC access (P < .001). There was marked variation among the 11 centers in the means of vascular access used for hemodialysis. Significant variation in infection rates was observed among the centers when controlling for types of access. CONCLUSIONS: There was a hierarchy of risk of hemodialysis-related bloodstream infection according to type of vascular access. There was significant variation in the type of vascular access being used among the Canadian hemodialysis centers, and also variation in access-specific infection rates between centers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.057
Threshold uncertainty score0.115

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.003
Science and technology studies0.0020.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.326
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations121
Published2002
Admission routes2
Has abstractyes

Explore more

Same venueInfection Control and Hospital EpidemiologySame topicCentral Venous Catheters and HemodialysisFrench-language works237,207