MétaCan
Menu
Back to cohort
Record W2117868338 · doi:10.1089/08942680260473506

Performance of Large- and Small-Volume Valved Holding Chambers with a New Combination Long-Term Bronchodilator/Anti-inflammatory Formulation Delivered by Pressurized Metered Dose Inhaler

2002· article· en· W2117868338 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Aerosol Medicine · 2002
Typearticle
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsTrudell Medical International (Canada)
Fundersnot available
KeywordsMetered-dose inhalerInhalerFluticasone propionateBronchodilatorMedicineAnesthesiaInhalationAnimal scienceAsthmaInternal medicine

Abstract

fetched live from OpenAlex

The treatment of both the bronchoconstriction and inflammatory aspects of asthma simultaneously by a single pressurized metered dose inhaler (pMDI) represents a significant advance in convenience to the patient. However, a valved holding chamber (VHC) may still be needed to reduce the coarse component of the dose that is likely to deposit in the oropharyngeal region, and a small sized device may offer significant advantages to the patient from the standpoint of compliance with therapy. VHCs representing small (adult AeroChamber Plus with mouthpiece, 149-mL) and large (Volumatic, 750-mL) devices have been compared in an in vitro evaluation with Seretide/Advair (hydro-fluoro alkane [HFA]-formulated fluticasone propionate [FP = 125 microg/dose] and salmeterol xinafoate [SX = 25 microg/dose]) by Andersen Mark-II eight-stage impactor operated at 28.3 L/min following compendial methodology. Fine particle fraction, based on the size range from 1.1 to 4.7 microm aerodynamic diameter, from either large or small VHCs with either component (69-79%) was similar [p > or = 0.08], and significantly greater than that from the pMDI alone (approximately 40%) [p < 0.001]. Fine particle dose emitted by the VHCs for SX (8.2 +/- 0.8 microg for the AeroChamber Plus and 7.7 +/- 0.5 microg for the Volumatic) were comparable, and also similar to the fine particle dose delivered by the pMDI when used without a VHC (7.6 +/- 0.6 microg). Fine particle doses for the FP component delivered by the two VHCs (46.4 +/- 3.4 microg for the AeroChamber Plus and 46.3 +/- 2.7 microg for the Volumatic) were equivalent, but were slightly greater than the corresponding fine particle dose from the pMDI alone (39.1 +/- 2.6 microg). However, this difference (approximately 20%) is close to the limit of resolution based on intermeasurement variability and is unlikely to have clinical significance, given the interpatient variability seen with inhaled drug therapy. It is therefore concluded that either of these VHCs has equivalent in vitro performance with this combination formulation in terms of the portion of the dose emitted from the pMDI that is likely to reach the receptors in the lungs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.314
Threshold uncertainty score0.669

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.249
Teacher spread0.227 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it