MétaCan
Menu
Back to cohort
Record W2118867026 · doi:10.1080/09205063.2014.907669

Surface modification of polydimethylsiloxane with a covalent antithrombin–heparin complex to prevent thrombosis

2014· article· en· W2118867026 on OpenAlexafffund
Jennifer Leung, Leslie R. Berry, Anthony K.C. Chan, John L. Brash

Bibliographic record

VenueJournal of Biomaterials Science Polymer Edition · 2014
Typearticle
Languageen
FieldMedicine
TopicHemostasis and retained surgical items
Canadian institutionsThrombosis and Atherosclerosis Research InstituteMcMaster UniversityHamilton Health Sciences
FundersHamilton Health Sciences FoundationMcMaster University
KeywordsAntithrombinChemistryPEG ratioContact angleCovalent bondPolydimethylsiloxaneHeparinPolymer chemistryPolyethylene glycolMoietySurface modificationProtein adsorptionBiophysicsPolymerOrganic chemistryBiochemistryMaterials science

Abstract

fetched live from OpenAlex

To prevent coagulation in contact with blood, polydimethylsiloxane (PDMS) was modified with an antithrombin-heparin (ATH) covalent complex using polyethylene glycol (PEG) as a linker/spacer. Using NHS chemistry, ATH was attached covalently to the distal chain end of the immobilized PEG linker. Surfaces were characterized by contact angle and X-ray photoelectron spectroscopy; attachment was confirmed by decrease in contact angles and an increase in nitrogen content as determined by X-ray photoelectron spectroscopy. Protein interactions in plasma were investigated using radiolabeled proteins added to plasma as tracers, and by immunoblotting of eluted proteins. Modification of PDMS with PEG alone was effective in reducing non-specific protein adsorption; attachment of ATH at the distal end of the PEG chains did not significantly affect protein resistance. It was shown that surfaces modified with ATH bound antithrombin selectively from plasma through the pentasaccharide sequence on the heparin moiety of ATH, indicating the ability of the ATH-modified surfaces to inhibit coagulation. Using thromboelastography, the effect of ATH modification on plasma coagulation was evaluated directly. It was found that initiation of coagulation was delayed and the time to clot was prolonged on PDMS modified with ATH/PEG compared to controls. For comparison, surfaces modified in a similar way with heparin were prepared and investigated using the same methods. The data suggest that the ATH-modified surfaces have superior anticoagulant properties compared to those modified with heparin.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.341
Teacher spread0.292 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomaterials Science Polymer EditionSame topicHemostasis and retained surgical itemsFrench-language works237,207