MétaCan
Menu
Back to cohort
Record W2139167922 · doi:10.3109/10929080801969725

Electromagnetic navigation improves minimally invasive robot-assisted lung brachytherapy

2008· article· en· W2139167922 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueComputer Aided Surgery · 2008
Typearticle
Languageen
FieldMedicine
TopicLung Cancer Diagnosis and Treatment
Canadian institutionsWestern University
Fundersnot available
KeywordsInvasive surgeryBrachytherapyRobotComputer scienceMinimally invasive proceduresComputer visionArtificial intelligenceMedical physicsMedicineRadiologySurgeryRadiation therapy

Abstract

fetched live from OpenAlex

OBJECTIVE: Recent advances in minimally invasive thoracic surgery have renewed an interest in the role of interstitial brachytherapy for lung cancer. Our previous work has demonstrated that a minimally invasive robot-assisted (MIRA) lung brachytherapy system produced results that were equal to or better than those obtained with standard video-assisted thoracic surgery (VATS) and comparable to results with open surgery. The purpose of this project was to evaluate the performance of an integrated system for MIRA lung brachytherapy that incorporated modified electromagnetic navigation and ultrasound image guidance with robotic assistance. METHODS: The experimental test-bed consisted of a VATS box, ZEUS and AESOP surgical robotic arms, a seed injector, an ultrasound machine, video monitors, a computer, and an endoscope. Our previous custom-designed electromagnetic navigational software and the robotic controller were modified and incorporated into the MIRA III system to become the next-generation MIRA IV. Inactive brachytherapy seeds were injected as close as possible to a small metal ball target embedded in an opaque agar cube. The completion time, the number of attempts, and the accuracy of seed deployment were compared for manual placement, standard VATS, MIRA III, and the new MIRA IV system. RESULTS: The MIRA IV system significantly reduced the median procedure time by 61% (104 s to 41 s), tissue trauma by 75% (4 attempts to 1 attempt), and mean seed placement error by 64% (2.5 mm to 0.9 mm) when compared to a standard VATS. MIRA IV also reduced the mean procedure time by 48% (85 s to 44 s) and the seed placement error by 68% (2.8 mm to 0.9 mm) compared to the MIRA III system. CONCLUSIONS: A modified integrated system for performing minimally invasive robot-assisted lung brachytherapy was developed that incorporated electromagnetic navigation and an improved robotic controller. The MIRA IV system performed significantly better than standard VATS and better than MIRA III.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.420
Threshold uncertainty score0.862

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.257
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it