MétaCan
Menu
Back to cohort
Record W2148566864 · doi:10.1053/euhj.2000.2476

Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials

2000· review· en· W2148566864 on OpenAlexaffabout
Stuart J. Connolly

Bibliographic record

VenueEuropean Heart Journal · 2000
Typereview
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsHamilton Health Sciences
Fundersnot available
KeywordsMedicineHazard ratioImplantable cardioverter-defibrillatorAmiodaroneVentricular fibrillationVentricular tachycardiaInternal medicineConfidence intervalCardiologyEjection fractionSudden cardiac deathDefibrillationProportional hazards modelRandomized controlled trialAtrial fibrillationHeart failure

Abstract

fetched live from OpenAlex

AIMS: Three randomized trials of implantable cardioverter defibrillator (ICD) therapy vs medical treatment for the prevention of death in survivors of ventricular fibrillation or sustained ventricular tachycardia have been reported with what might appear to be different results. The present analysis was performed to obtain the most precise estimate of the efficacy of the ICD, compared to amiodarone, for prolonging survival in patients with malignant ventricular arrhythmia. METHODS AND RESULTS: Individual patient data from the Antiarrhythmics vs Implantable Defibrillator (AVID) study, the Cardiac Arrest Study Hamburg (CASH) and the Canadian Implantable Defibrillator Study (CIDS) were merged into a master database according to a pre-specified protocol. Proportional hazard modelling of individual patient data was used to estimate hazard ratios and to investigate subgroup interactions. Fixed effect meta-analysis techniques were also used to evaluate treatment effects and to assess heterogeneity across studies. The classic fixed effects meta-analysis showed that the estimates of ICD benefit from the three studies were consistent with each other (P heterogeneity=0.306). It also showed a significant reduction in death from any cause with the ICD; with a summary hazard ratio (ICD:amiodarone) of 0.72 (95% confidence interval 0.60, 0.87;P=0.0006). For the outcome of arrhythmic death, the hazard ratio was 0.50 (95% confidence interval 0.37, 0.67;P<0.0001). Survival was extended by a mean of 4.4 months by the ICD over a follow-up period of 6 years. Patients with left ventricular ejection fraction < or = 35% derived significantly more benefit from ICD therapy than those with better preserved left ventricular function. Patients treated before the availability of non-thoracotomy ICD implants derived significantly less benefit from ICD therapy than those treated in the non-thoracotomy era. CONCLUSION: Results from the three trials of the ICD vs amiodarone are consistent with each other. There is a 28% reduction in the relative risk of death with the ICD that is due almost entirely to a 50% reduction in arrhythmic death.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.035
metaresearch head score (Gemma)0.062
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Meta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.996
Threshold uncertainty score0.185

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0350.062
Meta-epidemiology (narrow)0.0040.001
Meta-epidemiology (broad)0.0190.056
Bibliometrics0.0070.007
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0030.002
Research integrity0.0020.003
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.410
GPT teacher head0.440
Teacher spread0.031 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1,117
Published2000
Admission routes2
Has abstractyes

Explore more

Same venueEuropean Heart JournalSame topicCardiac pacing and defibrillation studiesFrench-language works237,207