MétaCan
Menu
Back to cohort
Record W2165727930 · doi:10.1148/radiol.2363040577

MR Angiography of Aortoiliac Occlusive Disease: A Phase III Study of the Safety and Effectiveness of the Blood-Pool Contrast Agent MS-325

2005· article· en· W2165727930 on OpenAlexaff
Mathias Goyen, Pierre Perreault, Elaine O'Riordan, Hernán Bertoni, James Taylor, Daniel Siragusa, Mel J. Sharafuddin, Emile R. Mohler, R K Breger, E. Kent Yucel, Kohkan Shamsi, Robert M. Weisskoff

Bibliographic record

VenueRadiology · 2005
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsLondon Health Sciences CentreHôpital Saint-Luc
Fundersnot available
KeywordsMedicineRadiologyAngiographyStenosisMagnetic resonance angiographyReceiver operating characteristicDiagnostic accuracyVascular diseaseConfidence intervalMagnetic resonance imagingSurgeryInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate prospectively the safety and effectiveness of aortoiliac magnetic resonance (MR) angiography enhanced with MS-325 (gadofosveset trisodium) at a dose of 0.03 mmol/kg; effectiveness was defined as accuracy relative to the reference standard, conventional angiography. MATERIALS AND METHODS: Study was approved by institutional review boards of participating institutions, and required national approvals were obtained. Study protocol conformed to Good Clinical Practice guidelines, and informed patient consent was obtained. Patients with known or suspected peripheral vascular disease received 0.03 mmol/kg MS-325 for aortoiliac MR angiography. They were also examined with conventional angiography. MS-325-enhanced MR was evaluated for safety and effectiveness. Along with unenhanced two-dimensional time-of-flight MR angiography, it was compared with conventional angiography for presence of vascular stenosis. Student t tests were used to identify significant improvement in diagnostic sensitivity, specificity, and accuracy, as well as quantitative characterization of stenoses by three blinded readers. Correlations between readers of conventional angiograms were calculated and compared with MR results. RESULTS: In 174 patients, MS-325-enhanced MR angiography showed significant improvement (P < or = .001) in sensitivity, specificity, and accuracy for diagnosis of clinically significant (> or =50%) stenosis, compared with unenhanced MR. For all readers, areas under the receiver operating characteristic curve for both quantitative and qualitative measures of significant disease increased (P < .001) for MS-325-enhanced MR compared with time-of-flight MR. All readers also expressed higher confidence in diagnosis (P < .001) and found fewer images uninterpretable with MS-325 enhancement. All measures of interpretation accuracy approached corresponding measures of correlation between readers of conventional angiograms. Incidence of severe and serious adverse events with MS-325 was low. No patients were withdrawn from study due to adverse events or abnormalities in laboratory results. There were no clinically important trends in findings at hematology, blood chemistry, urinalysis, electrocardiography, or physical examination. CONCLUSION: MR angiography with MS-325 provides significant improvement in effectiveness over unenhanced MR (and minimal and transient side effects) at a dose of 0.03 mmol/kg and was safe and effective for MR evaluation of patients with aortoiliac occlusive disease.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.304
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations105
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueRadiologySame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207