MétaCan
Menu
Back to cohort

Randomized Controlled Trial of Radiation Protection With a Patient Lead Shield and a Novel, Nonlead Surgical Cap for Operators Performing Coronary Angiography or Intervention

2015· article· en· W2209715654 on OpenAlexaffabout
Ashraf Alazzoni, Chris Gordon, Jaffer Syed, Madhu K. Natarajan, Michael Rokoss, Jon-David Schwalm, Shamir R. Mehta, Tej Sheth, Nicholas Valettas, James L. Velianou, Shaheen Pandie, Darar Al Khdair, Michael Tsang, Brandi Meeks, Kiersten Colbran, Ed Waller, Shun Fu Lee, Tamara Marsden, Sanjit S. Jolly

Bibliographic record

VenueCirculation Cardiovascular Interventions · 2015
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsOntario Tech UniversityPopulation Health Research Institute
Fundersnot available
KeywordsMedicineKermaLead apronNuclear medicineLead (geology)Radiation protectionConfidence intervalRadiation exposureRandomized controlled trialShieldAngiographySurgeryRadiologyDosimetryInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Interventional cardiologists receive one of the highest levels of annual occupational radiation exposure. Further measures to protect healthcare workers are needed. METHODS AND RESULTS: We evaluated the efficacy of a pelvic lead shield and a novel surgical cap in reducing operators' radiation exposure. Patients undergoing coronary angiography or percutaneous coronary intervention (n=230) were randomized to have their procedure with or without a lead shield (Ultraray Medical, Oakville, Canada) placed over the patient. During all procedures, operators wore the No Brainer surgical cap (Worldwide Innovations and Technology, Kansas City, KS) designed to protect the head from radiation exposure. The coprimary outcomes for the lead shield comparison were (1) operator dose (µSv) and (2) operator dose indexed for air kerma (µSv/mGy). For the cap comparison, the primary outcome was the difference between total radiation dose (µSv; internal and external to cap). The lead shield use resulted in a 76% reduction in operator dose (mean dose, 3.07; 95% confidence interval [CI], 2.00-4.71 µSv lead shield group versus 12.57; 95% CI, 8.14-19.40 µSv control group; P<0.001). The mean dose indexed for air kerma was reduced by 72% (0.004; 95% CI, 0.003-0.005 µSv/mGy lead shield group versus 0.015; 95% CI, 0.012-0.019 µSv/mGy control group; P<0.001). The cap use resulted in a significant reduction in operator head radiation exposure (mean left temporal difference [external-internal] radiation dose was 4.79 [95% CI, 3.30-6.68] µSv; P<0.001). CONCLUSIONS: The use of a pelvic lead shield and the cap reduced significantly the operator radiation exposure and can be easily incorporated into clinical practice. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02128035.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.007
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0040.003
Bibliometrics0.0010.000
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0030.004
Insufficient payload (model declined to judge)0.0100.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.297
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations54
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueCirculation Cardiovascular InterventionsSame topicRadiation Dose and ImagingFrench-language works237,207