MétaCan
Menu
Back to cohort
Record W2320877891 · doi:10.1021/ac501660a

Unique Ion Filter: A Data Reduction Tool for GC/MS Data Preprocessing Prior to Chemometric Analysis

2014· article· en· W2320877891 on OpenAlexafffund
Lawrence A. Adutwum, James J. Harynuk

Bibliographic record

VenueAnalytical Chemistry · 2014
Typearticle
Languageen
FieldEngineering
TopicAdvanced Chemical Sensor Technologies
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of CanadaGenome AlbertaGenome Canada
KeywordsChemometricsFeature selectionChemistryData reductionPattern recognition (psychology)Dimensionality reductionData setLinear discriminant analysisRaw dataData pre-processingReduction (mathematics)Filter (signal processing)Artificial intelligenceData miningChromatographyComputer scienceStatisticsMathematics

Abstract

fetched live from OpenAlex

Using raw GC/MS data as the X-block for chemometric modeling has the potential to provide better classification models for complex samples when compared to using the total ion current (TIC), extracted ion chromatograms/profiles (EIC/EIP), or integrated peak tables. However, the abundance of raw GC/MS data necessitates some form of data reduction/feature selection to remove the variables containing primarily noise from the data set. Several algorithms for feature selection exist; however, due to the extreme number of variables (10(6)-10(8) variables per chromatogram), the feature selection time can be prolonged and computationally expensive. Herein, we present a new prefilter for automated data reduction of GC/MS data prior to feature selection. This tool, termed unique ion filter (UIF), is a module that can be added after chromatographic alignment and prior to any subsequent feature selection algorithm. The UIF objectively reduces the number of irrelevant or redundant variables in raw GC/MS data, while preserving potentially relevant analytical information. In the m/z dimension, data are reduced from a full spectrum to a handful of unique ions for each chromatographic peak. In the time dimension, data are reduced to only a handful of scans around each peak apex. UIF was applied to a data set of GC/MS data for a variety of gasoline samples to be classified using partial least-squares discriminant analysis (PLS-DA) according to octane rating. It was also applied to a series of chromatograms from casework fire debris analysis to be classified on the basis of whether or not signatures of gasoline were detected. By reducing the overall population of candidate variables subjected to subsequent variable selection, the UIF reduced the total feature selection time for which a perfect classification of all validation data was achieved from 373 to 9 min (98% reduction in computing time). Additionally, the significant reduction in included variables resulted in a concomitant reduction in noise, improving overall model quality. A minimum of two um/z and scan window of three about the peak apex could provide enough information about each peak for the successful PLS-DA modeling of the data as 100% model prediction accuracy was achieved. It is also shown that the application of UIF does not alter the underlying chemical information in the data.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.015
Threshold uncertainty score0.051

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.008
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0050.004
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0020.002
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0150.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.297
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2014
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207