MétaCan
Menu
Back to cohort
Record W2332653577 · doi:10.1056/nejm200005113421902

Effects of Physiologic Pacing versus Ventricular Pacing on the Risk of Stroke and Death Due to Cardiovascular Causes

2000· article· en· W2332653577 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueNew England Journal of Medicine · 2000
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsUniversity of TorontoWestern UniversityUniversity of OttawaMontreal Heart InstituteUniversity of CalgaryMcGill UniversityUniversity of British ColumbiaMcMaster University
Fundersnot available
KeywordsMedicineAtrial fibrillationCardiologyStroke (engine)Internal medicineRandomized controlled trialVentricular pacingHeart failure

Abstract

fetched live from OpenAlex

BACKGROUND: Evidence suggests that physiologic pacing (dual-chamber or atrial) may be superior to single-chamber (ventricular) pacing because it is associated with lower risks of atrial fibrillation, stroke, and death. These benefits have not been evaluated in a large, randomized, controlled trial. METHODS: At 32 Canadian centers, patients without chronic atrial fibrillation who were scheduled for a first implantation of a pacemaker to treat symptomatic bradycardia were eligible for enrollment. We randomly assigned patients to receive either a ventricular pacemaker or a physiologic pacemaker and followed them for an average of three years. The primary outcome was stroke or death due to cardiovascular causes. Secondary outcomes were death from any cause, atrial fibrillation, and hospitalization for heart failure. RESULTS: A total of 1474 patients were randomly assigned to receive a ventricular pacemaker and 1094 to receive a physiologic pacemaker. The annual rate of stroke or death due to cardiovascular causes was 5.5 percent with ventricular pacing, as compared with 4.9 percent with physiologic pacing (reduction in relative risk, 9.4 percent; 95 percent confidence interval, -10.5 to 25.7 percent [the negative value indicates an increase in risk]; P=0.33). The annual rate of atrial fibrillation was significantly lower among the patients in the physiologic-pacing group (5.3 percent) than among those in the ventricular-pacing group (6.6 percent), for a reduction in relative risk of 18.0 percent (95 percent confidence interval, 0.3 to 32.6 percent; P=0.05). The effect on the rate of atrial fibrillation was not apparent until two years after implantation. The observed annual rates of death from all causes and of hospitalization for heart failure were lower among the patients with a physiologic pacemaker than among those with a ventricular pacemaker, but not significantly so (annual rates of death, 6.6 percent with ventricular pacing and 6.3 percent with physiologic pacing; annual rates of hospitalization for heart failure, 3.5 percent and 3.1 percent, respectively). There were significantly more perioperative complications with physiologic pacing than with ventricular pacing (9.0 percent vs. 3.8 percent, P<0.001). CONCLUSIONS: Physiologic pacing provides little benefit over ventricular pacing for the prevention of stroke or death due to cardiovascular causes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.680
Threshold uncertainty score0.282

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.259
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it