MétaCan
Menu
Back to cohort
Record W2344415502 · doi:10.1109/jbhi.2016.2524646

Motion Artifact Suppression in Impedance Pneumography Signal for Portable Monitoring of Respiration: An Adaptive Approach

2016· article· en· W2344415502 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

fundA Canadian funder is recorded on the work.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueIEEE Journal of Biomedical and Health Informatics · 2016
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsnot available
FundersUniversity of British ColumbiaUniversity of Michigan
KeywordsAdaptive filterSIGNAL (programming language)Filter (signal processing)Computer scienceArtifact (error)Signal processingIndependent component analysisRecursive least squares filterLeast mean squares filterControl theory (sociology)MathematicsArtificial intelligenceAlgorithmComputer visionTelecommunications

Abstract

fetched live from OpenAlex

The focus of this paper is motion artifact (MA) reduction from the impedance pneumography (IP) signal, which is widely used to monitor respiration. The amplitude of the MA that contaminates the IP signal is often much larger than the amplitude of the respiratory component of the signal. Moreover, the morphology and frequency composition of the artifacts may be very similar to that of the respiration, making it difficult to remove these artifacts. The proposed filter uses a regularization term to ensure that the pattern of the filtered signal is similar to that of respiration. It also ensures that the amplitude of the filter output is within the expected range of the IP signal by imposing an ε-tube on the filtered signal. The adaptive ε-tube filter is 100 times faster than the previously proposed nonadaptive version and achieves higher accuracies. Moreover, the experimental results, using several different performance measures, suggest that the proposed method outperforms popular MA reduction methods such as normalized least mean squares (NLMS) and recursive least squares (RLS) as well as independent component analysis (ICA). When used to extract the respiratory rate, the adaptive ε-tube achieves a mean error of 1.27 breaths per minute (BPM) compared to 4.72 and 4.63 BPM for the NLMS and RLS filters, respectively. When compared to the ICA algorithm, the proposed filter has an error of 1.06 BPM compared to 3.47 BPM for ICA. The statistical analyses indicate that all of the reported performance improvements are significant.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.703
Threshold uncertainty score0.289

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.298
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it