MétaCan
Menu
Back to cohort
Record W2344415502 · doi:10.1109/jbhi.2016.2524646

Motion Artifact Suppression in Impedance Pneumography Signal for Portable Monitoring of Respiration: An Adaptive Approach

2016· article· en· W2344415502 on OpenAlexfundno aff
Sardar Ansari, Kevin R. Ward, Kayvan Najarian

Bibliographic record

VenueIEEE Journal of Biomedical and Health Informatics · 2016
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsnot available
FundersUniversity of British ColumbiaUniversity of Michigan
KeywordsAdaptive filterSIGNAL (programming language)Filter (signal processing)Computer scienceArtifact (error)Signal processingIndependent component analysisRecursive least squares filterLeast mean squares filterControl theory (sociology)MathematicsArtificial intelligenceAlgorithmComputer visionTelecommunications

Abstract

fetched live from OpenAlex

The focus of this paper is motion artifact (MA) reduction from the impedance pneumography (IP) signal, which is widely used to monitor respiration. The amplitude of the MA that contaminates the IP signal is often much larger than the amplitude of the respiratory component of the signal. Moreover, the morphology and frequency composition of the artifacts may be very similar to that of the respiration, making it difficult to remove these artifacts. The proposed filter uses a regularization term to ensure that the pattern of the filtered signal is similar to that of respiration. It also ensures that the amplitude of the filter output is within the expected range of the IP signal by imposing an ε-tube on the filtered signal. The adaptive ε-tube filter is 100 times faster than the previously proposed nonadaptive version and achieves higher accuracies. Moreover, the experimental results, using several different performance measures, suggest that the proposed method outperforms popular MA reduction methods such as normalized least mean squares (NLMS) and recursive least squares (RLS) as well as independent component analysis (ICA). When used to extract the respiratory rate, the adaptive ε-tube achieves a mean error of 1.27 breaths per minute (BPM) compared to 4.72 and 4.63 BPM for the NLMS and RLS filters, respectively. When compared to the ICA algorithm, the proposed filter has an error of 1.06 BPM compared to 3.47 BPM for ICA. The statistical analyses indicate that all of the reported performance improvements are significant.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.298
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations36
Published2016
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Journal of Biomedical and Health InformaticsSame topicNon-Invasive Vital Sign MonitoringFrench-language works237,207