Fall Risk Classification in Community-Dwelling Older Adults Using a Smart Wrist-Worn Device and the Resident Assessment Instrument-Home Care: Prospective Observational Study
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
Background: Little is known about whether off-the-shelf wearable sensor data can contribute to fall risk classification or complement clinical assessment tools such as the Resident Assessment Instrument-Home Care (RAI-HC). Methods: A prospective, observational study was conducted among 3 faller groups (G0, G1, G2+) based on the number of previous falls (0, 1, ≥2 falls) in a sample of older community-dwelling adults. Each participant was requested to wear a smart wristband for 7 consecutive days while carrying out day-to-day activities in their normal lives. The wearable and RAI-HC assessment data were analyzed and utilized to create fall risk classification models, with 3 supervised machine learning algorithms: logistic regression, decision tree, and random forest (RF). Results: Of 40 participants aged 65 to 93 years, 16 (40%) had no previous falls, whereas 8 (20%) and 16 (40%) had experienced 1 and multiple (≥2) falls, respectively. Level of PA as measured by average daily steps was significantly different between groups (P=.04). In the 3 faller group classification, RF achieved the best accuracy of 83.8% using both wearable and RAI-HC data, which is 13.5% higher than that of using the RAI-HC data only and 18.9% higher than that of using wearable data exclusively. In discriminating between {G0+G1} and G2+, RF achieved the best area under the receiver operating characteristic curve of 0.894 (overall accuracy of 89.2%) based on wearable and RAI-HC data. Discrimination between G0 and {G1+G2+} did not result in better classification performance than that between {G0+G1} and G2+. Conclusions: Both wearable data and the RAI-HC assessment can contribute to fall risk classification. All the classification models revealed that RAI-HC outperforms wearable data, and the best performance was achieved with the combination of 2 datasets. Future studies in fall risk assessment should consider using wearable technologies to supplement resident assessment instruments.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.003 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it