MétaCan
Menu
Back to cohort
Record W2785508426 · doi:10.1089/dia.2017.0353

Overnight Glucose Control with Dual- and Single-Hormone Artificial Pancreas in Type 1 Diabetes with Hypoglycemia Unawareness: A Randomized Controlled Trial

2018· article· en· W2785508426 on OpenAlexafffund
Alexander Abitbol, Rémi Rabasa‐Lhoret, Virginie Messier, Laurent Legault, Mohamed Raef Smaoui, Ahmad Haidar

Bibliographic record

VenueDiabetes Technology & Therapeutics · 2018
Typearticle
Languageen
FieldMedicine
TopicDiabetes Management and Research
Canadian institutionsMcGill UniversityMontreal Children's HospitalDiabetes CanadaLMC Diabetes & Endocrinology (Canada)Université de MontréalMontreal Clinical Research InstituteMcGill University Health Centre
FundersInstitut de Recherche Clinique De Montréal
KeywordsHypoglycemiaMedicineArtificial pancreasInternal medicineGlucagonEndocrinologyHormoneInterquartile rangeDiabetes mellitusPancreasInsulinType 1 diabetes

Abstract

fetched live from OpenAlex

BACKGROUND: The dual-hormone (insulin and glucagon) artificial pancreas may be justifiable in some, but not all, patients. We sought to compare dual- and single-hormone artificial pancreas systems in patients with hypoglycemia unawareness and documented nocturnal hypoglycemia. METHODS: We conducted a randomized crossover trial comparing the efficacy of dual- and single-hormone artificial pancreas systems in controlling plasma glucose levels over the course of one night's sleep. We recruited 18 adult participants with hypoglycemia unawareness and 17 participants with hypoglycemia awareness, all of whom had documented nocturnal hypoglycemia during 2 weeks of screening. Outcomes were calculated using plasma glucose. RESULTS: In participants with hypoglycemia unawareness, the median (interquartile range [IQR]) percentage of time that plasma glucose was below 4.0 mmol/L was 0% (0-0) on dual-hormone artificial pancreas nights and 0% (0-10) on single-hormone artificial pancreas nights (P = 0.20). Additionally, participants with hypoglycemia unawareness experienced two hypoglycemic events (<3.0 mmol/L) on dual-hormone artificial pancreas nights and three hypoglycemic events on single-hormone artificial pancreas nights. In participants with hypoglycemia awareness, the median (IQR) percentage of time that plasma glucose was below 4.0 mmol/L was 0% (0-0) on both dual- and single-hormone artificial pancreas nights. Hypoglycemia awareness participants experienced zero hypoglycemic events on dual-hormone artificial pancreas nights and one event on single-hormone artificial pancreas nights. DISCUSSION: In this study, dual-hormone and single-hormone systems performed equally well in preventing nocturnal hypoglycemia in participants with hypoglycemia unawareness. Longer studies over the course of multiple days and nights may be needed to explore possible specific benefits in this population. ClinicalTrials.gov No. NCT02282254.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.004
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0030.003
Insufficient payload (model declined to judge)0.0060.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.256
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations38
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueDiabetes Technology & TherapeuticsSame topicDiabetes Management and ResearchFrench-language works237,207