MétaCan
Menu
Back to cohort
Record W2887138527 · doi:10.1186/s10195-018-0492-0

Are clinical outcomes affected by type of plate used for management of mid-shaft clavicle fractures?

2018· article· en· W2887138527 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueJournal of Orthopaedics and Traumatology · 2018
Typearticle
Languageen
FieldMedicine
TopicShoulder and Clavicle Injuries
Canadian institutionsMcGill UniversityMcGill University Health Centre
Fundersnot available
KeywordsClavicleMedicineInternal fixationSurgeryImplantFixation (population genetics)Implant failureReduction (mathematics)Orthopedic surgeryOrthodontics

Abstract

fetched live from OpenAlex

BACKGROUND: Open reduction and internal fixation (ORIF) using plate osteosynthesis for midshaft clavicle fractures is often complicated by the prominence of the implant due to the subcutaneous position of the clavicle. Reoperation rates for symptomatic clavicle plate removal have been reported to be as high as 53%. We sought to determine to which degree do clinical outcomes (all cause reoperation rate and rate of fracture union) differ between types of clavicle plates. MATERIALS AND METHODS: A retrospective chart review was performed using our hospital database for patients treated with ORIF for mid-shaft clavicle fractures (OTA/AO type 15-B). Implants included in this review were 2.7 mm reconstruction plates, 3.5 mm reconstruction plates, 3.5 mm precontoured clavicle plates and 3.5 mm locking compression plates. The primary outcome measure was the all cause reoperation rate. Secondary outcomes compared the rate fracture union, documented infection, hardware failures and clinical symptoms at the surgical site among the various plate types. Data was collected and descriptive statistics were analyzed. p values < 0.05 were considered statistically significant. RESULTS: A total of 102 midshaft clavicle fractures treated with ORIF were included in this study. The majority of patients were ≤ 50 years old (83.3%) and male (72.5%). The overall union rate for all plating constructs was 97.1%. We found that age, sex and smoking were not associated with the rate of re-operation. In addition, the fracture classification, type of implant used and number of screws used didn't increase the risk of revision surgery. In addition, more than 50% of patients complaining of pain at 6 weeks post-operatively required a second surgery for removal of hardware. Moreover, there was no association between age, sex, smoking, fracture classification or plate type and the rate of union. Interestingly, clavicle fractures fixed with 3.5 mm reconstruction plates were more likely to have hardware failure due to plastic deformation, whereas 2.7 mm plates were more likely to fail by plate breakage. CONCLUSION: Although different types of implants have different biomechanical properties, no difference in reoperation, union and plate removal rates were found between the various plate types. Future studies with a larger sample size are required to further examine these outcomes. LEVEL OF EVIDENCE: Level III.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.343

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.457
Teacher spread0.407 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it