Clinical optoacoustic imaging combined with ultrasound for coregistered functional and anatomical mapping of breast tumors
Bibliographic record
Abstract
Optoacoustic imaging, based on the differences in optical contrast of blood hemoglobin and oxyhemoglobin, is uniquely suited for the detection of breast vasculature and tumor microvasculature with the inherent capability to differentiate hypoxic from the normally oxygenated tissue. We describe technological details of the clinical ultrasound (US) system with optoacoustic (OA) imaging capabilities developed specifically for diagnostic imaging of breast cancer. The combined OA/US system provides co-registered and fused images of breast morphology based upon gray scale US with the functional parameters of total hemoglobin and blood oxygen saturation in the tumor angiogenesis related microvasculature based upon OA images. The system component that enabled clinical utility of functional OA imaging is the hand-held probe that utilizes a linear array of ultrasonic transducers sensitive within an ultrawide-band of acoustic frequencies from 0.1 MHz to 12 MHz when loaded to the high-impedance input of the low-noise analog preamplifier. The fiberoptic light delivery system integrated into a dual modality probe through a patented design allowed acquisition of OA images while minimizing typical artefacts associated with pulsed laser illumination of skin and the probe components in the US detection path. We report technical advances of the OA/US imaging system that enabled its demonstrated clinical viability. The prototype system performance was validated in well-defined tissue phantoms. Then a commercial prototype system named Imagio™ was produced and tested in a multicenter clinical trial termed PIONEER. We present examples of clinical images which demonstrate that the spatio-temporal co-registration of functional and anatomical images permit radiological assessment of the vascular pattern around tumors, microvascular density of tumors as well as the relative values of the total hemoglobin [tHb] and blood oxygen saturation [sO2] in tumors relative to adjacent normal breast tissues. The co-registration technology enables increased accuracy of radiologist assessment of malignancy by confirming, upgrading and/or downgrading US categorization of breast tumors according to Breast Imaging Reporting And Data System (BI-RADS). Microscopic histologic examinations on the biopsied tissue of the imaged tumors served as a gold standard in verifying the functional and anatomic interpretations of the OA/US image feature analysis.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.001 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".