MétaCan
Menu
Back to cohort
Record W3161341270 · doi:10.1186/s12985-021-01574-4

Comparison of SARS-CoV-2 indirect and direct RT-qPCR detection methods

2021· article· en· W3161341270 on OpenAlexafffund
Joel D. Pearson, Daniel Trcka, Suying Lü, Sharon J. Hyduk, Mark Jen, Marie-Ming Aynaud, J. Javier Hernández, Philippos Peidis, Miriam Barrios‐Rodiles, Kin Chan, Tony Mazzulli, Liliana Attisano, Laurence Pelletier, Myron I. Cybulsky, Jeffrey L. Wrana, Rod Bremner

Bibliographic record

VenueVirology Journal · 2021
Typearticle
Languageen
FieldMedicine
TopicSARS-CoV-2 detection and testing
Canadian institutionsUniversity Health NetworkSinai Health SystemToronto General HospitalLunenfeld-Tanenbaum Research InstituteUniversity of Toronto
FundersCanadian Institutes of Health ResearchKrembil Foundation
KeywordsRNA extractionBiologyDetection limitVirologyReal-time polymerase chain reactionRNARNase PTaqManGold standard (test)Computational biologyChromatographyGeneChemistryMedicineGenetics

Abstract

fetched live from OpenAlex

BACKGROUND: Sensitive, rapid, and accessible diagnostics continue to be critical to track the COVID-19 pandemic caused by the SARS-CoV-2 virus. RT-qPCR is the gold standard test, and comparison of methodologies and reagents, utilizing patient samples, is important to establish reliable diagnostic pipelines. METHODS: Here, we assessed indirect methods that require RNA extraction with direct RT-qPCR on patient samples. Four different RNA extraction kits (Qiagen, Invitrogen, BGI and Norgen Biotek) were compared. For detection, we assessed two recently developed Taqman-based modules (BGI and Norgen Biotek), a SYBR green-based approach (NEB Luna Universal One-Step Kit) with published and newly-developed primers, and clinical results (Seegene STARMag RNA extraction system and Allplex 2019-nCoV RT-qPCR assay). We also tested and optimized direct, extraction-free detection using these RT-qPCR systems and performed a cost analysis of the different methods evaluated here. RESULTS: copies of viral genome/μl. However, the BGI detection system is more expensive than other options tested here. With direct RT-qPCR, simply adding an RNase inhibitor greatly improved detection, without the need for any other treatments (e.g. lysis buffers or boiling). The best direct methods detected ~ 10 fold less virus than indirect methods, but this simplified approach reduced sample handling, as well as assay time and cost. CONCLUSIONS: With extracted RNA, the BGI RT-qPCR detection system exhibited superior performance over the Norgen system, matching initial clinical diagnosis with the Seegene Allplex assay. The BGI system was also suitable for direct, extraction-free analysis, providing 78.4% sensitivity. The Norgen system, however, still accurately detected samples with a clinical Ct < 33 from extracted RNA, provided significant cost savings, and was superior to SYBR green assays that exhibited reduced specificity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.012
Threshold uncertainty score0.062

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0120.011
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0020.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0050.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.119
GPT teacher head0.435
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2021
Admission routes2
Has abstractyes

Explore more

Same venueVirology JournalSame topicSARS-CoV-2 detection and testingFrench-language works237,207