KeywordsThermostatHVACOccupancyCluster analysisZoningComputer scienceBuilding automationTemperature controlMeasure (data warehouse)Series (stratigraphy)Environmental scienceEfficient energy useCluster (spacecraft)Data miningArchitectural engineeringEngineeringControl engineeringCivil engineeringAir conditioningMechanical engineeringArtificial intelligence

Abstract

fetched live from OpenAlex

An efficient building should be able to control its internal temperature in a manner that considers both the building's energy efficiency and the comfort level of its occupants. Thermostats help to control the temperature within a building by providing real-time data on the temperature inside that space to determine whether it is within the acceptable range of that building's control system, and proper thermostat placement helps to better control a building's temperature. More thermostats can provide better control of a building, as well as a better understanding of the building's temperature distribution. In order to determine the minimum number of thermostats required to accurately measure and control the internal temperature distribution of a building, it is necessary to find the locations that show similar environmental conditions. In this paper, we analyzed high resolution temperature measurements from a commercial building using wireless sensors to assess the performance and health of the building's HVAC zoning and controls system. Then we conducted two cluster analyses to evaluate the efficiency of the existing zoning structure and to find the optimal number of clusters. K-means and time series clustering were used to identify the temperature clusters per building floor. Based on statistical assessments, we observed that time series clustering showed better results than k-means clustering.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.047
Threshold uncertainty score0.093

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.003
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.189
Teacher spread0.183 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations49
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueEnergy InformaticsSame topicAdvanced Chemical Sensor TechnologiesFrench-language works237,207