MétaCan
Menu
Back to cohort
Record W4320070369 · doi:10.2196/40463

Iterative Development, Validation, and Certification of a Smartphone System to Assess Neonatal Jaundice: Development and Usability Study

2023· article· en· W4320070369 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueJMIR Pediatrics and Parenting · 2023
Typearticle
Languageen
FieldMedicine
TopicNeonatal Health and Biochemistry
Canadian institutionsnot available
FundersAkershus UniversitetssykehusEuropean CommissionNorges Teknisk-Naturvitenskapelige Universitet
KeywordsUsabilityJaundiceMedicineCertificationMedical emergencyPediatricsMedical physicsComputer scienceSurgeryOperating system

Abstract

fetched live from OpenAlex

BACKGROUND: Medical device development is an area facing multiple challenges, resulting in a high number of products not reaching the clinical setting. Neonatal hyperbilirubinemia, manifesting as neonatal jaundice (NNJ), is an important cause of newborn morbidity and mortality. It is important to identify infants with neonatal hyperbilirubinemia at an early stage, but currently there is a lack of tools that are both accurate and affordable. OBJECTIVE: This study aimed to develop a novel system to assess the presence of NNJ. The device should provide accurate results, be approved as a medical device, be easy to use, and be produced at a price that is affordable even in low-resource settings. METHODS: We used an iterative approach to develop a smartphone-based system to detect the presence of NNJ. We performed technical development, followed by clinical and usability testing in parallel, after which we initiated the regulatory processes for certification. We updated the system in each iteration, and the final version underwent a clinical validation study on healthy term newborns aged 1 to 15 days before all documentation was submitted for conformity assessment to obtain Conformité Européenne (CE) certification. We developed a system that incorporates a smartphone app, a color calibration card, and a server. RESULTS: Three iterations of the smartphone-based system were developed; the final version was approved as a medical device after complying with Medical Device Regulation guidelines. A total of 201 infants were included in the validation study. Bilirubin values using the system highly correlated with total serum or plasma bilirubin levels (r=0.84). The system had a high sensitivity (94%) to detect severe jaundice, defined as total serum or plasma bilirubin >250 µmol/L, and maintained a high specificity (71%). CONCLUSIONS: Our smartphone-based system has a high potential as a tool for identifying NNJ. An iterative approach to product development, conducted by working on different tasks in parallel, resulted in a functional and successful product. By adhering to the requirements for regulatory approval from the beginning of the project, we were able to develop a market-ready mobile health solution.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.035
Threshold uncertainty score0.406

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.344
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it