MétaCan
Menu
Back to cohort
Record W4399992451 · doi:10.2196/53643

Reliable Contactless Monitoring of Heart Rate, Breathing Rate, and Breathing Disturbance During Sleep in Aging: Digital Health Technology Evaluation Study

2024· article· en· W4399992451 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueJMIR mhealth and uhealth · 2024
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsnot available
Fundersnot available
KeywordsHeart rate variabilityPreprintBreathingHeart rateSleep (system call)Disturbance (geology)mHealthMedicineComputer scienceInternal medicineAnesthesiaWorld Wide Web

Abstract

fetched live from OpenAlex

Background Longitudinal monitoring of vital signs provides a method for identifying changes to general health in an individual, particularly in older adults. The nocturnal sleep period provides a convenient opportunity to assess vital signs. Contactless technologies that can be embedded into the bedroom environment are unintrusive and burdenless and have the potential to enable seamless monitoring of vital signs. To realize this potential, these technologies need to be evaluated against gold standard measures and in relevant populations. Objective We aimed to evaluate the accuracy of heart rate and breathing rate measurements of 3 contactless technologies (2 undermattress trackers, Withings Sleep Analyzer [WSA] and Emfit QS [Emfit]; and a bedside radar, Somnofy) in a sleep laboratory environment and assess their potential to capture vital signs in a real-world setting. Methods Data were collected from 35 community-dwelling older adults aged between 65 and 83 (mean 70.8, SD 4.9) years (men: n=21, 60%) during a 1-night clinical polysomnography (PSG) test in a sleep laboratory, preceded by 7 to 14 days of data collection at home. Several of the participants (20/35, 57%) had health conditions, including type 2 diabetes, hypertension, obesity, and arthritis, and 49% (17) had moderate to severe sleep apnea, while 29% (n=10) had periodic leg movement disorder. The undermattress trackers provided estimates of both heart rate and breathing rate, while the bedside radar provided only the breathing rate. The accuracy of the heart rate and breathing rate estimated by the devices was compared with PSG electrocardiogram-derived heart rate (beats per minute) and respiratory inductance plethysmography thorax-derived breathing rate (cycles per minute), respectively. We also evaluated breathing disturbance indexes of snoring and the apnea-hypopnea index, available from the WSA. Results All 3 contactless technologies provided acceptable accuracy in estimating heart rate (mean absolute error <2.12 beats per minute and mean absolute percentage error <5%) and breathing rate (mean absolute error ≤1.6 cycles per minute and mean absolute percentage error <12%) at 1-minute resolution. All 3 contactless technologies were able to capture changes in heart rate and breathing rate across the sleep period. The WSA snoring and breathing disturbance estimates were also accurate compared with PSG estimates (WSA snore: r2=0.76; P<.001; WSA apnea-hypopnea index: r2=0.59; P<.001). Conclusions Contactless technologies offer an unintrusive alternative to conventional wearable technologies for reliable monitoring of heart rate, breathing rate, and sleep apnea in community-dwelling older adults at scale. They enable the assessment of night-to-night variation in these vital signs, which may allow the identification of acute changes in health, and longitudinal monitoring, which may provide insight into health trajectories. International Registered Report Identifier (IRRID) RR2-10.3390/clockssleep6010010

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.333
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it