MétaCan
Menu
Back to cohort
Record W4400860367 · doi:10.1016/s2589-7500(24)00118-3

Computer-aided detection of tuberculosis from chest radiographs in a tuberculosis prevalence survey in South Africa: external validation and modelled impacts of commercially available artificial intelligence software

2024· article· en· W4400860367 on OpenAlexfundaboutno aff
Zhi Zhen Qin, Martie van der Walt, Sizulu Moyo, Farzana Ismail, Phaleng Maribe, Claudia M. Denkinger, Sarah Zaidi, Rachael Barrett, Lindiwe Mvusi, Nkateko Mkhondo, Khangelani Zuma, Samuel Manda, Lisa Koeppel, Thuli Mthiyane

Bibliographic record

VenueThe Lancet Digital Health · 2024
Typearticle
Languageen
FieldMedicine
TopicCOVID-19 diagnosis using AI
Canadian institutionsnot available
FundersGovernment of CanadaWorld Health Organization
KeywordsTuberculosisSoftwareMedicineRadiographyMedical physicsArtificial intelligenceComputer scienceRadiologyPathology

Abstract

fetched live from OpenAlex

BACKGROUND: Computer-aided detection (CAD) can help identify people with active tuberculosis left undetected. However, few studies have compared the performance of commercially available CAD products for screening in high tuberculosis and high HIV settings, and there is poor understanding of threshold selection across products in different populations. We aimed to compare CAD products' performance, with further analyses on subgroup performance and threshold selection. METHODS: We evaluated 12 CAD products on a case-control sample of participants from a South African tuberculosis prevalence survey. Only those with microbiological test results were eligible. The primary outcome was comparing products' accuracy using the area under the receiver operating characteristic curve (AUC) against microbiological evidence. Threshold analyses were performed based on pre-defined criteria and across all thresholds. We conducted subgroup analyses including age, gender, HIV status, previous tuberculosis history, symptoms presence, and current smoking status. FINDINGS: Of the 774 people included, 516 were bacteriologically negative and 258 were bacteriologically positive. Diverse accuracy was noted: Lunit and Nexus had AUCs near 0·9, followed by qXR, JF CXR-2, InferRead, Xvision, and ChestEye (AUCs 0·8-0·9). XrayAME, RADIFY, and TiSepX-TB had AUC under 0·8. Thresholds varied notably across these products and different versions of the same products. Certain products (Lunit, Nexus, JF CXR-2, and qXR) maintained high sensitivity (>90%) across a wide threshold range while reducing the number of individuals requiring confirmatory diagnostic testing. All products generally performed worst in older individuals, people with previous tuberculosis, and people with HIV. Variations in thresholds, sensitivity, and specificity existed across groups and settings. INTERPRETATION: Several previously unevaluated products performed similarly to those evaluated by WHO. Thresholds differed across products and demographic subgroups. The rapid emergence of products and versions necessitates a global strategy to validate new versions and software to support CAD product and threshold selections. FUNDING: Government of Canada.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.034
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.045

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.034
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.085
GPT teacher head0.325
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations48
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueThe Lancet Digital HealthSame topicCOVID-19 diagnosis using AIFrench-language works237,207