MétaCan
Menu
Retour à la cohorte
Enregistrement W1528968714 · doi:10.1002/14651858.cd007260.pub3

Mechanical versus manual chest compressions for cardiac arrest

2014· review· en· W1528968714 sur OpenAlexaff
Steven C. Brooks, Nizar Hassan, Blair L. Bigham, Laurie J. Morrison

Notice bibliographique

RevueCochrane Database of Systematic Reviews · 2014
Typereview
Langueen
DomaineMedicine
ThématiqueCardiac Arrest and Resuscitation
Établissements canadiensUniversity of TorontoSt. Michael's HospitalKingston General HospitalQueen's University
Organismes subventionnairesnon disponible
Mots-clésMedicineCardiopulmonary resuscitationMEDLINERandomized controlled trialMeta-analysisEmergency medicineResuscitationSurgeryInternal medicine

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Mechanical chest compression devices have been proposed to improve the effectiveness of cardiopulmonary resuscitation (CPR). OBJECTIVES: To assess the effectiveness of resuscitation strategies using mechanical chest compressions versus resuscitation strategies using standard manual chest compressions with respect to neurologically intact survival in patients who suffer cardiac arrest. SEARCH METHODS: On 19 August 2017 we searched the Cochrane Central Register of Controlled Studies (CENTRAL), MEDLINE, Embase, Science Citation Index-Expanded (SCI-EXPANDED) and Conference Proceedings Citation Index-Science databases. Biotechnology and Bioengineering Abstracts and Science Citation abstracts had been searched up to November 2009 for prior versions of this review. We also searched two clinical trials registries for any ongoing trials not captured by our search of databases containing published works: Clinicaltrials.gov (August 2017) and the World Health Organization International Clinical Trials Registry Platform portal (January 2018). We applied no language restrictions. We contacted experts in the field of mechanical chest compression devices and manufacturers. SELECTION CRITERIA: We included randomised controlled trials (RCTs), cluster-RCTs and quasi-randomised studies comparing mechanical chest compressions versus manual chest compressions during CPR for patients with cardiac arrest. DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. MAIN RESULTS: We included five new studies in this update. In total, we included 11 trials in the review, including data from 12,944 adult participants, who suffered either out-of-hospital cardiac arrest (OHCA) or in-hospital cardiac arrest (IHCA). We excluded studies explicitly including patients with cardiac arrest caused by trauma, drowning, hypothermia and toxic substances. These conditions are routinely excluded from cardiac arrest intervention studies because they have a different underlying pathophysiology, require a variety of interventions specific to the underlying condition and are known to have a prognosis different from that of cardiac arrest with no obvious cause. The exclusions were meant to reduce heterogeneity in the population while maintaining generalisability to most patients with sudden cardiac death.The overall quality of evidence for the outcomes of included studies was moderate to low due to considerable risk of bias. Three studies (N = 7587) reported on the designated primary outcome of survival to hospital discharge with good neurologic function (defined as a Cerebral Performance Category (CPC) score of one or two), which had moderate quality evidence. One study showed no difference with mechanical chest compressions (risk ratio (RR) 1.07, 95% confidence interval (CI) 0.82 to 1.39), one study demonstrated equivalence (RR 0.79, 95% CI 0.60 to 1.04), and one study demonstrated reduced survival (RR 0.41, CI 0.21 to 0.79). Two other secondary outcomes, survival to hospital admission (N = 7224) and survival to hospital discharge (N = 8067), also had moderate quality level of evidence. No studies reported a difference in survival to hospital admission. For survival to hospital discharge, two studies showed benefit, four studies showed no difference, and one study showed harm associated with mechanical compressions. No studies demonstrated a difference in adverse events or injury patterns between comparison groups but the quality of data was low. Marked clinical and statistical heterogeneity between studies precluded any pooled estimates of effect. AUTHORS' CONCLUSIONS: The evidence does not suggest that CPR protocols involving mechanical chest compression devices are superior to conventional therapy involving manual chest compressions only. We conclude on the balance of evidence that mechanical chest compression devices used by trained individuals are a reasonable alternative to manual chest compressions in settings where consistent, high-quality manual chest compressions are not possible or dangerous for the provider (eg, limited rescuers available, prolonged CPR, during hypothermic cardiac arrest, in a moving ambulance, in the angiography suite, during preparation for extracorporeal CPR [ECPR], etc.). Systems choosing to incorporate mechanical chest compression devices should be closely monitored because some data identified in this review suggested harm. Special attention should be paid to minimising time without compressions and delays to defibrillation during device deployment.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,005
score de la tête « metaresearch » (Gemma)0,006
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: Revue systématique
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,462
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0050,006
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0130,004
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,126
Tête enseignante GPT0,423
Écart entre enseignants0,296 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeRevue systématique
Domainenon disponible
GenreSynthèse

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations155
Publié2014
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueCochrane Database of Systematic ReviewsMême sujetCardiac Arrest and ResuscitationTravaux en français237 207