Assessment of high voltage auto-transformer spare requirements in bulk transmission systems
Notice bibliographique
Résumé
High voltage auto-transformers represent an important component of bulk transmission systems and are used to transform voltage from one level to another. These auto-transformers are critical for regional load supply, inter-regional load transfers and for certain generator/load connections. Major or catastrophic failures to this equipment can have severe consequences to electric utilities in terms of increased operating costs and customer load losses. To minimize the impact of this type of failures, utilities may carry some spare units to guard against such events. These spare units are going to cost utilities money (utility cost) to purchase, to store and to maintain and utilities should try to strike the right balance between the utility cost and the risk cost (if spare units are not there). This paper describes a probabilistic approach for assessing the risk associated with catastrophic failures of auto-transformers used in bulk transmission systems with and without availability of spare units. The computed risk will be expressed in dollars and will be added to the cost of carrying any spare units. The required number of spare units (optimal) is obtained when the total cost, utility and risk costs, is minimal. Sensitivity studies are carried out to determine the system parameters that have dominant impacts on the optimal number of spares. An example is presented to illustrate the proposed assessment methodology.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».