Fire endurance of FRP-strengthened reinforced concrete columns
Notice bibliographique
Résumé
In buildings, fire represents one of the most severe environmental conditions and should thus be properly accounted for in the design of structural members. In recent years, there has been an increase in the use of fibre-reinforced polymer (FRP) materials for reinforcement and strengthening of concrete structures in buildings, and this has raised concerns regarding the behaviour of such FRP systems in fire. There is currently very little information available on the fire endurance of FRP-reinforced or strengthenedconcrete systems. This paper presents results from full-scale fire resistance experiments on two FRP-strengthened (wrapped) reinforced concrete (RC) columns. A comparison is made between the fire performances of FRP-strengthened RC columns and a conventional unstrengthened RC column tested previously. Data obtained during the experiments is used to show that the fire behaviour of FRP-wrapped concrete columns, using an appropriate fire protection system, is as good as that of unstrengthened RC columns. Thecritical factors that influence the fire endurance of FRP-reinforced concrete columns, namely the fire protection system, FRP wrapping, loading, and type of aggregate in the concrete, are discussed. It is demonstrated that satisfactory fire resistance ratings for FRP-wrapped concrete columns can be obtained by properly incorporating appropriate fire protection measures into the overall structural system.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».