Estimation of bilirubin using BiliChek™, a transcutaneous bilirubin measurement device: Effects of gestational age and use of phototherapy
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
BACKGROUND: Heel puncture to obtain bilirubin measurements is painful for infants and distressing for parents. Transcutaneous bilirubin measurement using BiliChek (Respironics, USA) is easily performed in any setting. Reliable transcutaneous testing should decrease the number of painful procedures in otherwise well infants, reduce the volume of phlebotomy losses in ill newborns, and reduce the need for hospital or specialized clinic visits after discharge. OBJECTIVE: To correlate bilirubin measurements using the transcutaneous device BiliChek with 'gold standard' serum measurements in well term infants, and in ill term and preterm infants admitted to the authors' neonatal intensive care unit. METHODS: The study consisted of two phases. In phase 1, informed consent was obtained from mothers of 99 healthy, full-term infants not receiving phototherapy to perform both serum and transcutaneous bilirubin measurements at the time of heel puncture for routine neonatal screening. In phase 2, 56 infants in the neonatal intensive care unit had a total of 99 transcutaneous readings performed at the time serum bilirubin measurements were ordered for clinical reasons by the attending staff. The operators of the transcutaneous device, who were unaware of the serum bilirubin levels, performed readings within 1 h of the heel puncture. RESULTS: Using a Bland-Altman comparison in the well term infants, the transcutaneous measurements were -32.2 mumol/L to +31.2 mumol/L (1.96 SD); however, 79 (79.8%) of the transcutaneous measurements were within 15 mumol/L of the serum measurements. The variation in preterm infants was greater at -69.6 mumol/L to +62.0 mumol/L, and only 49 (49.5%) were within 15 mumol/L. For infants receiving phototherapy, the variation was -76.3 mumol/L to +49.5 mumol/L, but improved to -40.4 mumol/L to +31.0 mumol/L if an area of skin was patched for testing, approximating the group not receiving phototherapy. CONCLUSIONS: Transcutaneous bilirubin measurements obtained with the BiliChek instrument were accurate for measuring bilirubin levels in term jaundiced infants not receiving phototherapy and in those receiving phototherapy if an area of skin was patched. The instrument was not as sensitive in the small sample of preterm infants, and a larger study is required before recommending the use of this instrument in this population.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle