MétaCan
Menu
Retour à la cohorte
Enregistrement W1562623253 · doi:10.1111/j.1532-5415.2011.03565.x

PILOTING A RENAL DRUG ALERT SYSTEM FOR PRESCRIBING TO RESIDENTS IN LONG‐TERM CARE

2011· letter· en· W1562623253 sur OpenAlexafffundabout
Courtney Kennedy, Glenda Campbell, Amit X. Garg, Jackie Stroud, Ruth E. McCallum, Αλεξάνδρα Παπαϊωάννου

Notice bibliographique

RevueJournal of the American Geriatrics Society · 2011
Typeletter
Langueen
DomaineHealth Professions
ThématiqueElectronic Health Records Systems
Établissements canadiensSt. Joseph’s Healthcare HamiltonInstitute for Clinical Evaluative SciencesWestern UniversityMcMaster University
Organismes subventionnairesCanadian Institutes of Health Research
Mots-clésMedicinePharmacyMedical prescriptionPolypharmacyPharmacistLong-term careDeprescribingClinical decision support systemGeriatricsClinical pharmacyFamily medicineMedical emergencyHealth careIntensive care medicineNursing

Résumé

récupéré en direct d'OpenAlex

To the Editor: Approximately 40% of long-term care (LTC) residents have some degree of renal impairment,1 and 42% have received at least one prescription that was inappropriate because of their renal function.2 To assist LTC physicians with the challenge of prescribing to older adults with renal impairment, a computerized clinical decision support system (CDSS) was developed in partnership with a large pharmacy provider that generated renal prescribing alerts. Because of several barriers, including considerable personnel and acquisition costs to develop and implement the CDSS and limited information technology infrastructure, it has not been widely adopted in the LTC setting.3 It has been successfully implemented and tested in two academic LTC homes, but site-specific adaptation and substantial personnel commitment were needed.3,4 The role of the consultant pharmacist was seen as essential for implementation of CDSS.3 The results of a pilot evaluation in seven LTC homes across Ontario, Canada, are presented below. Based on a literature review and consulting well-known sources,5,6 an expert panel (including five specialists in geriatrics, nephrology, and academic and consultant pharmacists) provided recommendations for 25 medications that had good evidence for renal dose adjustments. Final recommendations were programmed into the central prescription database of the pharmacy provider. Figure 1 provides an operational flowchart of the CDSS. If a resident's creatinine clearance (CrCl) was below the identified threshold for a medication, a prescribing alert was automatically printed. Acting as the gatekeeper, the consultant pharmacist prescreened alerts for relevance (i.e., in some cases, the dose or drug was already appropriate) and added additional information based on chart review where applicable. Relevant alerts were given to the physician along with any additional advice. All standing prescriptions at baseline and any new orders over the following 3 months were checked on the CDSS. Flowchart for renal prescribing computerized clinical decision support system (CDSS). *At baseline, all current prescriptions were reviewed once, and after that only new prescription orders were reviewed. †An alert is generated if creatinine clearance is below the appropriate threshold for that medication. The total number of beds in the seven LTC homes was 1,196. The homes ranged in size from 10 to 370 beds (mean 171, median 144). During the 3-month program evaluation, 446 alerts were generated in 321 residents. The mean age of residents receiving an alert was 87.0±7.4, and 81% were female. Mean CrCl was 34.6±12.3. Twenty-seven percent of all residents received at least one alert. After prescreening, consultant pharmacists sent 63% (n=282) of the alerts to the physician. Physicians responded to 70% of these alerts with a dose change or medication discontinuation. The most common medications with an alert were digoxin, ranitidine, and metformin, accounting for approximately 45% of all alerts generated. In a telephone survey with five family physicians participating in the pilot project, all believed that recommendations were appropriate and clear. All had confidence in the alerts, and four rated the alerts as very helpful and one as somewhat helpful. The physicians cited their relationship with the consultant pharmacist and confidence in the expert panel as positive factors. Other factors that increased physicians' confidence with alerts were the specific recommendations provided and that the expert panel who developed the alerts were local and national opinion leaders. The high rate of physician response is contrary to other studies that have found that physicians ignore messages that are too frequent or deemed irrelevant or unnecessary.7–9 When excessive numbers of prescribing alerts are produced, clinicians often ignore them because of "alert fatigue." It was hypothesized that the pharmacist-mediated system streamlined the process and contributed to the high rate of physician response. The consultation with LTC physicians during the development phase maximized the relevance and user-friendliness of the alerts. This program overcame many cost-related and logistical barriers faced by LTC homes in implementing a CDSS.3,4,10 Initiating this project at the central pharmacy level enabled LTC homes to participate without implementing any additional infrastructure. Consultant pharmacists provided the extra support necessary, which is aligned with their role in LTC. In the future, even as LTC homes have greater access to computerized physician order entry, involving consultant pharmacists will be a valuable part of increasing the uptake of recommended prescribing practices. Further evaluation is required to determine whether this alert system reduces the number of adverse events, but this pilot project demonstrated that a pharmacist-mediated CDSS had a high rate of acceptance by LTC physicians. The pharmacy provider has implemented the CDSS across LTC homes in Ontario, Canada. As LTC homes increasingly adopt electronic technologies, more-widespread use of CDSS to support appropriate prescribing is a realistic and perhaps necessary goal. Further studies are needed to examine the potential gains in patient safety and cost-savings associated with CDSS use in LTC. We thank all the family physicians, consultant pharmacists, and nursing staff who participated in this pilot project. We also thank Medical Pharmacies Group Limited for their ongoing support of this project. Thank-you to Sheri Burns for her assistance with the physician interviews and qualitative methodology. Conflict of Interest: The editor in chief has reviewed the conflict of interest checklist provided by the authors and has determined that the authors have no financial or any other kind of personal conflicts with this paper. C. Campbell and J.B. Stroud are employees of Medical Pharmacies Group Limited, the company that implemented the CDSS in this study, but this program has not been trademarked or sold for commercial purposes. No profits were made from the implementation of this program. Funding for this project was received from a Canadian Institute of Health Research Knowledge Translation Grant (FRN: KTS-73426). Author Contributions: Courtney C. Kennedy: conception and design, data acquisition, analysis and interpretation of data, and drafting of the manuscript. Glenda Campbell: conception and design, development of prescribing alerts, testing and verification of the computer application, data acquisition, analysis and interpretation of data, and critical review of the manuscript. Amit X. Garg and Lisa Dolovich: conception and design, development of prescribing alerts, analysis and interpretation of data, and critical review of the manuscript. Jackie B. Stroud: conception and design; data acquisition; analysis and interpretation of data; critical review of the manuscript; coordination of the development, testing, and verification of the computer application. Ruth E. McCallum: critical revision and formatting of the manuscript and final approval of the manuscript. Alexandra Papaioannou: conception and design, development of prescribing alerts, data acquisition, analysis and interpretation of data, and critical review of the manuscript. Sponsor's Role: None.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,008
score de la tête « metaresearch » (Gemma)0,039
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Essai non randomisé · Signal consensuel: aucune
GenreSignal candidat: Éditorial · Signal consensuel: aucune
Score de désaccord entre enseignants0,068
Score d'incertitude au seuil0,135

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0080,039
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,001
Bibliométrie0,0010,000
Études des sciences et des technologies0,0020,001
Communication savante0,0020,001
Science ouverte0,0030,001
Intégrité de la recherche0,0030,001
Charge utile insuffisante (le modèle a refusé de juger)0,0040,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,047
Tête enseignante GPT0,376
Écart entre enseignants0,329 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeEssai non randomisé
Domainenon disponible
GenreÉditorial

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations8
Publié2011
Routes d'admission3
Résumé présentoui

Explorer davantage

Même revueJournal of the American Geriatrics SocietyMême sujetElectronic Health Records SystemsTravaux en français237 207