Prophylactic platelet transfusion for haemorrhage after chemotherapy and stem cell transplantation
Notice bibliographique
Résumé
BACKGROUND: Platelet transfusions are used in modern clinical practice to prevent and treat bleeding in thrombocytopenic patients with bone marrow failure. Although considerable advances have been made in platelet transfusion therapy in the last 30 years, some areas continue to provoke debate, especially the use of prophylactic platelet transfusions for the prevention of thrombocytopenic bleeding. OBJECTIVES: To determine the optimal use of platelet transfusion for the prevention of haemorrhage (prophylactic platelet transfusion) in patients with haematological malignancies undergoing chemotherapy or stem cell transplantation. SEARCH STRATEGY: Randomised controlled trials (RCTs) were searched for in the Cochrane Central Register of Controlled Trials (CENTRAL). Searching was also undertaken on the OVID versions of MEDLINE and EMBASE using an RCT search filter strategy. SELECTION CRITERIA: Randomised controlled trials involving transfusions of platelet concentrates, prepared either from individual units of whole blood or by apheresis, and given prophylactically to prevent bleeding in patients with haematological malignancies and receiving treatment with chemotherapy and/or stem cell transplantation. DATA COLLECTION AND ANALYSIS: All electronically derived citations and abstracts of papers identified by the review search strategy were initially screened for relevancy by one reviewer. Studies clearly irrelevant were excluded at this stage. The full text of all potentially relevant trials was then formally assessed for eligibility by two reviewers independently. Two reviewers completed data extraction independently. Missing data were requested from the original investigators, as appropriate. Disagreements were resolved by discussion with the other reviewers. MAIN RESULTS: Eight completed published trials, with a total of 390 participants in the intervention groups and 362 participants in the control groups, were included in the review for further analysis. The eight studies were classified as: * three trials relevant to prophylactic platelet transfusions versus therapeutic platelet transfusions; * three trials relevant to prophylactic platelet transfusion with one trigger level versus prophylactic platelet transfusion with another trigger level; * two trials relevant to prophylactic platelet transfusion with one dose schedule versus prophylactic platelet transfusion with another dose schedule. The few reports of controlled trials addressing prophylactic versus therapeutic transfusions contained small numbers of patients and were all undertaken over 25 years ago. None of these three studies explicitly clarified whether the lack of a reported difference was a reflection of insufficient power in the trials. The findings of the meta-analyses for this group of three small studies must be interpreted with caution. In contrast, more contemporary trials addressed the question of what platelet count thresholds should apply for prophylactic transfusion; three identified studies broadly compared platelet transfusion thresholds of 10 versus 20 x 109/litre for different clinical groups of patients. There were no statistically significant differences between the groups with regards to mortality, remission rates, number of participants with severe bleeding events or red cell transfusion requirements. However, it was unclear whether the studies had sufficient power to demonstrate in combination non-inferiority in terms of safety of the lower threshold, 10 x 109/litre. Insufficient randomised trials have been undertaken to make clinically relevant conclusions about the effect of different platelet doses. REVIEWERS' CONCLUSIONS: There are no reasons to change current practice but uncertainty about the practice of prophylactic transfusion therapy should be recognised, particularly in the light of concerns about the scenario that blood products, including platelets, could become an increasingly scarce resource in the future and for which adequate alternatives do not exist. Consideration should be given to developing adequately powered trials comparing strategies of prophylaxis versus therapeutic platelet transfusion.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,012 | 0,002 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».