Frequency considerations for deep ablation with high‐intensity focused ultrasound: A simulation study
Notice bibliographique
Résumé
PURPOSE: The objective of this study was to explore frequency considerations for large-volume, deep thermal ablations with focused ultrasound. Though focal patterns, focal steering rate, and the size of focal clusters have all been explored in this context, frequency studies have generally explored shallower depths and hyperthermia applications. This study examines both treatment efficiency and near-field heating rate as functions of frequency and depth. METHODS: Flat, 150 mm transducer arrays were simulated to operate at frequencies of 250, 500, 750, 1000, 1250, and 1500 kHz. Each array had λ2 interelement spacing yielding arrays of 2000-70 000 piston-shaped elements arranged in concentric rings. Depths of 50, 100, and 150 mm were explored, with attenuation (α) values of 2.5-10 (Np/m)/MHz. Ultrasound propagation was simulated with the Rayleigh-Sommerfeld integral over a volume of homogeneous simulated tissue. Absorbed power density was determined from the acoustic pressure which, in turn, was modeled with the Pennes bioheat transfer equation. Using this knowledge of temperature over time, thermal dose function of Sapareto and Dewey was used to model the resulting bioeffect of each simulated sonication. Initially, single foci at each depth, frequency, and α were examined with either fixed peak temperatures or fixed powers. Based on the size of the resulting, single foci lesions, larger compound sonications were designed with foci packed together in multiple layers and rings. For each depth, focal patterns were chosen to produce a similar total ablated volume for each frequency. These compound sonications were performed with a fixed peak temperature at each focus. The resulting energy efficiency (volume ablated per acoustic energy applied), near-field heating rate (temperature increase in the anterior third of the simulation space per unit volume ablated), and near- and far-field margins were assessed. RESULTS: Lesions of comparable volume were created with different frequencies at different depths. The results reflect the interconnected nature of frequency as it effects focal size (decreasing with frequency), peak pressure (generally increasing with frequency), and attenuation (also increasing with frequency). The ablation efficiency was the highest for α = 5 (Np/m)/MHz at a frequency of 750 kHz at each depth. For α = 10 (Np/m)/MHz, efficiency was the highest at 750 kHz for a depth of 50 mm, and 500 kHz at depths of 100 and 150 mm. At all sonication depths, near-field heating was minimized with lower frequencies of 250 and 500 kHz. CONCLUSIONS: Large-volume ablations are most efficient at frequencies of 500-750 kHz at depths of 100-150 mm. When one considers that near-field heat accumulation tends to be the rate limiting factor in large-volume ablations like uterine fibroid surgery, the results show that frequencies as low as 500 kHz are favored for their ability to reduce heating in the near-field.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».