Novel millimeter-wave slow-wave phase shifter using MEMS technology
Notice bibliographique
Résumé
A novel mm-wave MEMS phase shifter based on a slow wave structure is introduced. The phase shifter uses co-planer wave guide that has the signal line loaded with inductors through capacitive coupling. The inductor and the capacitive coupling capacitor are designed to work for the mm-wave frequency range. Integrated metal to metal RF MEMS switches are designed such that inductors can be shortened to ground to obtain a normal CPW when the switches are closed. When the switches are open, the signal is traveling in the slow wave structures and a phase shift is obtained. Unlike other phase shifters, the proposed design can handle higher power and does not have neither MEMS capacitive nor metal to metal switches on the signal line. The measured pull-in voltage is 45 volt. The phase shifter is designed, modeled, fabricated and tested. The phase shift per length is 355 °/cm. The phase shifter exhibits high resolution of phase shift while maintaining a return loss of 20 dB and a worst insertion loss of 3.21 dB at 60 GHz.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».