Effective labelling is difficult, but safety really does matter
Notice bibliographique
Résumé
The recent letter discussing the Poggendorf effect (Nott. Anaesthesia 2001; 56: 917) is helpful in understanding some of the complex psychological aspects of labelling and safety. His suggestion that a second person must also read the label before the administration of any drug is certainly of value, but raises a number of issues. The first concerns resource – a survey of New Zealand anaesthetists found that in only 1.5% of circumstances was a second person routinely available throughout the anaesthetic to check drugs before their administration [1]. The second, more important issue, however, relates to human fallibility. We have received a number of routine audit reports documenting errors made by nursing staff who have used a two-person check, but still got it wrong. Part of the problem seems to be the suggestibility of human beings. If the second person is shown a label and asked if it is indeed drug X, then there is a chance that he or she will read the label as drug X, even if it is in fact a similarly named but different drug. We have developed a new system designed to reduce the propensity for error during drug administration in anaesthesia [2]. One feature of this system is the use of large legible labels that include bar codes. When a syringe with such a label is scanned by the barcode reader just before administration, a computer speaks the name of the drug as a final check of the syringe's contents. The computer is of course not open to suggestion and our system has already demonstrated its ability to facilitate anaesthetists' efforts to avoid drug error. In this way, we have embodied the principle of the two-person check, in a manner that utilises a less expensive resource than a trained health professional, and that capitalises on the strength of machines in an area in which humans are prone to error. The approach also makes possible the inclusion of various alarms for expired drugs and allergy alerts. No safety system can be expected to eliminate errors and accidents entirely [2, 3]. We therefore agree with Dr␣Nott's statement that colour coding by class of drug will not eliminate error on its own. Neither will the use of the bar-coded ‘two-person check’ described above. However, we believe that each would be a significant improvement on the status quo, and both should be incorporated into a wide-ranging approach to error reduction, which includes (so far as possible) all aspects of the drug administration environment in theatre and indeed beyond [2, 4, 5]. The use of colour-coded (and bar-coded) user-applied syringe labels does nothing to address the problem of ampoule labelling. We have previously suggested that manufacturers should supply injectable drugs in appropriately labelled prefilled syringes to remove one error-prone step from the process of drug administration [4]. In reality, this will be a long time coming, and the current state of labelling on most ampoules can only be described as appalling. Figure 14 shows two ampoules from a drug trolley at our hospital, which were recently involved in a substitution near miss. These ampoules are compliant with the current NHS specification for ampoule labelling [6]. Yet, despite the fact that the figure shows the drug brand names facing forward (in the largest text on the ampoule), the ampoules remain very difficult to read and distinguish from one another. The black writing on clear glass is hard to read because the writing on the other side of the ampoule shows through and obscures critical information. The NHS specification suggests the use of a yellow background for the lettering on ampoules to increase legibility – but obviously it is simpler and allowable for manufacturers not to bother. The bands at the base of these ampoules may look like an identification aid such as the rings sometimes used to indicate the length of action of a drug [7], but they are in fact specialised barcodes (without expiry dates) used by the manufacturer (personal communication, Abbott Laboratories). We use custom-made prefilled syringes where practical in our new system [2, 4]. In addition we have designed a ‘flag’ or supplementary label attached to the ampoule by a licensed pharmaceutical manufacturer with a loop of clear plastic [2]. The flag label adds the drug name, drug class, its class-specific colour cue and a barcode, all in a highly legible manner, without obscuring any of the ampoule's original details (Fig. 15). When the contents of the ampoule are drawn up, the self-adhesive flag label can be removed and attached to the syringe as part of the drawing-up process. Consistent colour standards for user-applied syringe labels in anaesthesia already exist in Australia, New Zealand, Canada and the United States (discussed in [2]). In addition, ampoule standards also exist in Canada and the US, which allow the use of a colour-coded border, consistent with the aforementioned syringe label standards, around the␣‘critical information panel’– thus permitting the use of consistent ampoule and syringe label colour cues [8, 9]. Ampoule colour coding by class of drug was suggested 19 years ago, but remains undeveloped [7]. While it may be␣convenient from an administrative, bureaucratic or manufacturing perspective to have different standards for ampoules and syringes, this makes no sense in terms of the ergonomics and safety of a clinician administering a drug to a patient. There is no doubt that getting the detail of effective labelling standards right is difficult, but if safety really does matter [10], then these difficulties must be overcome. Resolution of these problems is long overdue.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,002 | 0,004 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,013 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».