A D-Q rotating frame DC-bus voltage controller for bi-directional single-phase AC/DC converters
Notice bibliographique
Résumé
This paper presents a closed-loop control technique in D-Q rotating frame for bi-directional single-phase AC/DC converters. The proposed control system allows the active and reactive power control in both directions from grid to vehicle and vehicle to grid, while controlling the DC-bus voltage. Due to the lack of freedom degrees required for orthogonal systems, using the D-Q frame is a challenge in single-phase power conditioning systems. In this paper, an all-pass filter has been used to generate the orthogonal signals in the closed-loop control system. This method generates the orthogonal signals without degrading the dynamics of the closed-loop control system and with less noise in comparison to the other common methods such as differentiators. A DC-bus voltage estimator based on adaptive filter has also been used in this paper to remove the double frequency ripple and in turn increase the reliability and speed of the proposed controller. The proposed control scheme is used to implement the smart charging and power management strategies of the residential loads using electric vehicles as a storage system. Simulation and experimental results demonstrate the transient and steady-state performance of the proposed controller in different modes of operation. Also the performance of the proposed DC-bus voltage estimator in removing the double frequency ripple as well as the application of the proposed control scheme in implementation of power management strategies in a typical household, has been shown by using simulation results.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».