MétaCan
Menu
Retour à la cohorte
Enregistrement W1925396565 · doi:10.1002/14651858.cd010293.pub2

Integrated versus non-integrated orbital implants for treating anophthalmic sockets

2016· review· en· W1925396565 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.

Notice bibliographique

RevueCochrane Database of Systematic Reviews · 2016
Typereview
Langueen
DomaineBiochemistry, Genetics and Molecular Biology
ThématiqueOcular Disorders and Treatments
Établissements canadiensMcMaster University
Organismes subventionnairesnon disponible
Mots-clésMedicineImplantMEDLINEClinical trialRandomized controlled trialAnophthalmiaCochrane LibraryMeta-analysisSurgeryInternal medicine

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Anophthalmia is the absence of one or both eyes, and it can be congenital (i.e. a birth defect) or acquired later in life. There are two main types of orbital implant: integrated, whereby the implant receives a blood supply from the body that allows for the integration of the prosthesis within the tissue; and non-integrated, where the implant remains separate. Despite the remarkable progress in anophthalmic socket reconstruction and in the development of various types of implants, there are still uncertainties about the real roles of integrated (hydroxyapatite (HA), porous polyethylene (PP), composites) and non-integrated (polymethylmethacrylate (PMMA)/acrylic and silicone) orbital implants in anophthalmic socket treatment. OBJECTIVES: To assess the effects of integrated versus non-integrated orbital implants for treating anophthalmic sockets. SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2016), Embase (January 1980 to August 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (1982 to August 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 8 August 2016. SELECTION CRITERIA: Randomised controlled trials (RCTs) and quasi-RCTs of integrated and non-integrated orbital implants for treating anophthalmic sockets. DATA COLLECTION AND ANALYSIS: Two authors independently selected relevant trials, assessed methodological quality and extracted data. MAIN RESULTS: We included three studies with a total of 284 participants (250 included in analysis). The studies were conducted in India, Iran and the Netherlands. The three studies were clinically heterogenous, comparing different materials and using different surgical techniques. None of the included studies used a peg (i.e. a fixing pin used to connect the implant to the prosthesis). In general the trials were poorly reported, and we judged them to be at unclear risk of bias.One trial compared HA using traditional enucleation versus alloplastic implantation using evisceration (N = 100). This trial was probably not masked. The second trial compared PP with scleral cap enucleation versus PMMA with either myoconjunctival or traditional enucleation (N = 150). Although participants were not masked, outcome assessors were. The last trial compared HA and acrylic using the enucleation technique (N = 34) but did not report comparative effectiveness data.In the trial comparing HA versus alloplastic implantation, there was no evidence of any difference between the two groups with respect to the proportion of successful procedures at one year (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.95 to 1.09, N = 100, low-certainty evidence). People receiving HA had slightly worse horizontal implant mobility compared to the alloplastic group (mean difference (MD) -3.35 mm, 95% CI -4.08 to -2.62, very low-certainty evidence) and slightly worse vertical implant motility (MD -2.76 mm, 95% CI -3.45 to -2.07, very low-certainty evidence). As different techniques were used - enucleation versus evisceration - it is not clear whether these differences in implant motility can be attributed solely to the type of material. Investigators did not report adverse events.In the trial comparing PP versus PMMA, there was no evidence of any difference between the two groups with respect to the proportion of successful procedures at one year (RR 0.92, 95% CI 0.84 to 1.01, N = 150, low-certainty evidence). There was very low-certainty evidence of a difference in horizontal implant motility depending on whether PP was compared to PMMA with traditional enucleation (MD 1.96 mm, 95% CI 1.01 to 2.91) or PMMA with myoconjunctival enucleation (-0.57 mm, 95% CI -1.63 to 0.49). Similarly, for vertical implant motility, there was very low-certainty evidence of a difference in the comparison of PP to PMMA traditional (MD 3.12 mm 95% CI 2.36 to 3.88) but no evidence of a difference when comparing PP to PMMA myoconjunctival (MD -0.20 mm 95% CI -1.28 to 0.88). Four people in the PP group (total N = 50) experienced adverse events (i.e. exposures) compared to 6/100 in the PMMA groups (RR 17.82, 95% CI 0.98 to 324.67, N = 150, very low-certainty evidence).None of the studies reported socket sphere size, cosmetic effect or quality of life measures. AUTHORS' CONCLUSIONS: Current very low-certainty evidence from three small published randomised controlled trials did not provide sufficient evidence to assess the effect of integrated and non-integrated material orbital implants for treating anophthalmic sockets. This review underlines the need to conduct further well-designed trials in this field.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,002
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: Revue systématique
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,196
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,002
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0050,002
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0010,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,072
Tête enseignante GPT0,375
Écart entre enseignants0,304 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle