Flow Visualization within the Liquid Phase of Pool Fire
Notice bibliographique
Résumé
The effects of altering the lower thermal boundary condition of a methanol pool from -5 °C to 50°C was investigated within a 90 mm diameter and 12 mm deep quartz burner under steady state burning condition in a quiescent air environment. The temperature and velocity within the liquid were measured by a single thermocouple traversed through the pool and PIV, respectively, in order to better understand the transport of mass and energy in the liquid. Temperature measurements revealed a distinct two-layer vertical thermal structure with the upper layer of the pool being almost uniform and near the boiling temperature of the fuel, while in the lower layer experienced an increasing temperature gradient as the bottom boundary temperature was lowered. The thickness of the thermally uniform layer increased as the bottom temperature was increased. The measured fluid velocity showed a complementary two-layer structure with the upper layer being dominated by a pair of counter-rotating vortices that kept this portion of the liquid well mixed and transferred heat from the hot pool wall to the pool center, while the flow in the lower layer was uniformly low in value and vertical.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».