A targeted sparse readout for multi-anode photo-multipliers and optically isolated crystals
Notice bibliographique
Résumé
Multi anode photo-multipliers are able to localize the position of a light source, and measure its intensity. Normally these devices have their anode wires connected to a resistor network. If the light originates in an optically collimated, pixilated scintillation crystal array, only a few of the anode wires receive any significant signal. If only those wires whose signal is above the noise threshold are used to localize the light, the signal-to-noise ratio improves (same signal but less noise). We found that only about 6 wires on each axis have a significant signal when a 511 keV gamma ray is detected in a 2 mm/spl times/2 mm BGO crystal. Using a custom made integrated circuit which provides the binary code of the address corresponding to the biggest of 16 analog inputs, and a sample-and-hold on each anode wire we hope to direct a six channel ADC to sample the anode wires which provide the best positioning signal on each axis of the PMT. The shape of the signal envelope permits identification of crystals which would otherwise be beyond the PMT's field of view. This readout should enhance these PMTs in application like positron emission mammography, and small animal PET imaging.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».