Native Arteriovenous Fistulas: Correlation of Intra‐Access Blood Flow with Characteristics of Stenoses Found During Diagnostic Angiography
Notice bibliographique
Résumé
Surveillance of the intra-access blood flow (Qa) has improved identification of thrombosis risk (Qa < or = 500 ml/minute), and these patients are referred for angiogram and angioplasty. The purpose of this study was to correlate the Qa with patient and stenotic lesion characteristics both before and after angioplasty in a retrospective cohort of 210 patients who were preselected on the basis of reduced Qa (369 +/- 121 ml/minute). Angiograms revealed a total of 643 stenoses, and all patients had at least one significant stenosis (>50% luminal narrowing). There was no significant association between the preangioplasty Qa and the number, location, or length of stenoses, but there was a significant negative correlation between the degree of stenosis and the preangioplasty Qa. Five hundred eighty stenoses in 190 patients were treated with angioplasty; the postangioplasty Qa was 633 +/- 208 ml/minute. Of the residual stenoses, all had less than 50% narrowing. There was no correlation between the postangioplasty Qa and the length or degree of stenoses, but there was a significant negative correlation between the postangioplasty Qa and the number of stenoses. We conclude that the primary determinant of reduced preangioplasty Qa is the degree of stenosis, when stenoses are over 50%, whereas the primary determinant of reduced postangioplasty Qa is the number of stenosis. For patients with two or more residual stenoses and failure to achieve Qa > 500 p;ml/minute postangioplasty, the alternative procedure is a prompt surgical revision in order to maintain the goal of access patency.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».