Antithrombin-Heparin Covalent Complex
Notice bibliographique
Résumé
BACKGROUND: The anticoagulant effect of heparinoids is attributed to their cofactor activity for antithrombin (AT) and heparin cofactor II. In patients with thrombosis, however, thrombin is often protected from AT-dependent, heparin-mediated inactivation. The purpose of this study was to compare the properties of unfractionated/standard heparin (UFH/SH) and those of a novel covalent AT-heparin complex (ATH) in a rabbit arterial thrombosis prevention and bleeding model. METHODS AND RESULTS: Thrombosis in the distal aorta was triggered by vessel wall injury and critical stenosis. Blood flow in the damaged arterial segment was monitored with a flow probe placed distal to the constrictor. Rabbits were given doses of SH (62.5 to 187.5 IU x kg(-1) x 90 min(-1)) or ATH (16 to 65 IU x kg(-1) x 90 min(-1)). Cumulative blood loss from skin incisions was used to assess drug safety. The antithrombotic effects of ATH were greater than those of SH as measured by clot weight, blood flow, and vessel patency; eg, complete thrombus resolution was achieved with ATH (33 to 65 IU/kg), but not SH (125.0 to 187.5 IU/kg). At doses that produced equivalent vessel patency (50% to 60%), blood loss induced by ATH (60.2 microL) was 2.6-fold lower (P<0.05) than that induced by SH (154.6 microL). CONCLUSIONS: In our experimental system, ATH was able to control arterial thrombosis more effectively than its SH precursor, without pronounced bleeding.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».