Inhibition of Microsurgical Thrombosis by the Platelet Glycoprotein IIb/IIIa Antagonist SR121566A
Notice bibliographique
Résumé
Despite major improvements in tools and significant refinements of techniques, microsurgical anastomosis still carries a significant risk of failure due to microvascular thrombosis. The key to improving the success of microvascular surgery may lie in the pharmacologic control of thrombus formation. Central to pathologic arterial thrombosis are platelets. Glycoprotein IIb/IIIa is a highly abundant platelet surface receptor that plays a major role in platelet aggregation by binding platelets to each other through the coagulation factor fibrinogen. To explore the ability of antithrombotic agents to prevent microvascular thrombosis, a rabbit ear artery model was used in which a standardized arterial injury results in predictable thrombus formation. This model was used to examine whether SR121566A, a specific and potent glycoprotein IIb/IIIa inhibitor, can successfully prevent microsurgical thrombosis. Using a coded, double-blind experimental design, 20 rabbits (40 arteries) were assigned to four treatment groups: (1) saline injection (n = 10), (2) acetylsalicylic acid 10 mg/kg (n = 10), (3) heparin 0.5 mg/kg bolus with subsequent intermittent boluses of 0.25 mg/kg every 30 minutes (n = 10), and (4) SR121566A 2 mg/kg bolus (n = 10). After vessel damage and clamp release, arteries were assessed for patency at 5, 30, and 120 minutes by the Acland refill test. Coagulation assays, in vivo bleeding times, and ex vivo platelet aggregation studies were also conducted. Scanning electron microscopy was used to examine mural thrombus composition.A significant, fourfold increase in vessel patency following administration of SR121566A over saline control (80 percent versus 20 percent patency, respectively, at 35 minutes after reperfusion, p < 0.01) was noted. This was correlated with marked inhibition of ex vivo platelet aggregation. This antiplatelet treatment did not prolong coagulation assays (mean international normalized ratio: saline, 0.66 +/- 0.04; SR121566A, 0.64 +/- 0.03; mean thromboplastin time: saline, 19.63 +/- 0.67; SR121566A, 17.87 +/- 3.27) and bleeding times (mean bleeding time: saline, 42 +/- 4; SR121566A, 48 +/- 6). Scanning electron microscopy demonstrated extensive platelet and fibrin deposition in control vessel thrombi. In contrast, thrombi from SR121566A-treated vessels demonstrated predominance of fibrin with few platelets when examined under scanning electron microscopy.Administration of SR121566A was associated with a significant increase in vessel patency, without deleterious effects on coagulation assays or bleeding times. The increase in vessel patency was correlated with inhibition of platelet aggregation and decreased platelet deposition, as demonstrated by scanning electron microscopy. Glycoprotein IIb/IIIa antagonists represent a new class of anti-platelet agents that may be suited for inhibiting microsurgical thrombosis. This study supports further investigation into the use of these agents in microsurgery.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».