Measurement of Low Air−Water Partition Coefficients of Organic Acids by Evaporation from a Water Surface
Notice bibliographique
Résumé
A novel system is described for the determination of the air−water partition coefficient ( K AW ) for substances that have low air−water partition coefficients, i.e., K AW < 10 -3, and may aggregate in solution, ionize, and display surface activity. The compound is evaporated isothermally from solution through an undisturbed air−water interface at a known gas flow rate, and its concentrations in the water and gas phases are measured. Although equilibrium is not achieved, the extent of departure from equilibrium can be determined using estimated mass transfer coefficients. K AW was determined for formic, acetic, benzoic, and perfluorooctanoic acids (PFOA), and assuming an approximately 50 % approach to equilibrium, which is in accord with theoretical prediction. Agreement with available literature data was satisfactory. The experimentally determined K AW of PFOA was 1.02·10 -3 with a standard deviation of 9.1 % ( n = 9). The method is suitable for fluorinated surfactants, aggregating and ionizing substances for which K AW may not be readily measured with existing techniques.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».