<i>In vitro</i> assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements
Notice bibliographique
Résumé
Modularity in total hip replacement offers advantages with regard to biomechanical adjustments and leg lengths. Recently, modular femoral necks were introduced as an added advantage to head modularity permitting further adjustments in femoral version as well as offset and ease of revision. Currently, most necks are made of Ti6Al4V for which cases of in vivo fractures and inseparable neck-stem junctions have been reported. Therefore, we investigated CoCrMo head-Ti6Al4V stem hip replacements with necks made of CoCrMo as an alternative to Ti6Al4V. We compared the two materials with respect to (1) compressive load bearing capacity; (2) fatigue durability; and (3) component distraction. We performed in vitro fatigue-pull-off, microscopy, fatigue durability and compression investigations. The CoCrMo neck showed a load bearing capacity of 18 kN, 38% higher than 13 kN for the Ti6Al4V neck. A fatigue load of 11.2 kN for 1 million cycle failure was achieved with CoCrMo translating into nearly 1000 times longer fatigue life compared to Ti6Al4V necks. The neck-stem distraction force showed large statistical variation and was similar for both neck materials. Overall, the results suggest a superiority of CoCrMo over Ti6Al4V as neck material with regard to mechanical behavior. However, the corrosion behavior was not appropriately assessed and necessitates additional investigations.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,006 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».