Coiled Time Domain Reflectometry Matric Potential Sensor
Notice bibliographique
Résumé
Matric potential is a measure of the combined capillary and adsorptive forces of soil particles and is imperative for determining both the direction and magnitude of water flow in unsaturated soils. Measuring soil matric potential in semiarid and arid environments is a challenge. Current methods cannot measure the entire range of values, from 0 to −1.5 MPa. The objective of this research was to develop a new sensor capable of measuring the relationship between the dielectric constant of a ceramic core and the range of field soil matric potential values. This instrument uses two Cu TDR rods wrapped around a dual‐threaded Plexiglas core, which is inserted into a porous ceramic block salvaged from damaged Campbell Scientific 229 heat dissipation sensors. The relationship of the ceramic's measured dielectric constant to soil matric potential is determined through a laboratory calibration curve. Calibration of the probe involved the use of a tension table and pressure plate apparatus. The dielectric constant of the probe was measured at a range of points between 0 and −1.5 MPa, and a modified van Genuchten water retention model was used to fit the data ( R 2 = 0.84). The proposed instrument provided an effective method of measuring soil matric potentials from 0 to −1.5 MPa.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».