The Kepler Intubation System
Notice bibliographique
Résumé
Our goal in this study was to develop a robotic intubation system and to conduct a feasibility pilot study on the use of a robotic intubation system for endotracheal intubations. The Kepler Intubation System was developed, consisting of a remote control center (joystick and intubation cockpit) linked to a standard videolaryngoscope via a robotic arm. Ninety intubations were performed by the Kepler Intubation System on an airway trainer mannequin by a single operator. The first group of 30 intubations was performed with the operator in direct view of the mannequin (direct view group). The second group of 30 intubations was performed with the operator unable to see the mannequin (indirect view group). Thirty semiautomated intubations were also performed during which the robotic system replayed a trace of a previously recorded intubation maneuver (semiautomated group). First-attempt success rates and intubation times for each trial were recorded. Trends were analyzed using linear regression. Data are presented as mean (SD). All intubations were successful at first attempt. The mean intubation times were 46 (18) seconds, 51 (19) seconds, and 41 (1) seconds for the direct view, indirect view, and semiautomated group, respectively. Both the direct and indirect view groups had a negative slope, denoting that each successive trial required less time. The semiautomated group had a slope of 0 and a low SD of 1 second, illustrating the high reproducibility of automated intubations. We concluded that a robotic intubation system has been developed that can allow remote intubations within 40 to 60 seconds.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».