Comment on the paper by Gibala, Little, Macdonald and Hawley entitled Physiological adaptations to low‐volume, high‐intensity interval training in health and disease
Notice bibliographique
Résumé
We have read with great interest the article of Gibala et al. 2012 published recently in The Journal of Physiology and their important review on physiological mechanisms of skeletal muscle and cardiovascular adaptations to high-intensity interval training (HIT) in apparently healthy subjects and patients with cardiovascular risk and/or heart disease. From a clinical perspective, and in agreement with the authors, we consider the use of Wingate-based HIT not possible in patients with cardiovascular (CV) risks or/and diseases due to major safety issues of this extremely demanding form of exercise. In their article, the authors report previous studies in patients with CV risks or/and cardiac diseases referring to the Norwegian high-intensity interval exercise (HIIE) protocol (Wisloff et al. 2007) and also present their own new practical HIIE model (10 × 60 s work bouts at 80–90% maximal heart rate or 60% of peak power) (Hood et al. 2011). For the Norwegian HIIE protocol, we have previously discussed their potential limitations (Guiraud et al. 2010). With respect to their valuable published work, we have several comments on the new HIIE model proposed by the authors. Firstly, exercise intensity at 60% of peak power cannot be considered as high intensity; secondly, the superiority of this HIIE protocol on physiological responses and/or adaptations compared with other existing HIIE or even moderate-intensity continuous exercise (MICE) needs to be demonstrated. Also, the use of heart rate for prescription and length of exercise interval (60 s) particularly in cardiac patients could be an important limitation of this model (Guiraud et al. 2010, 2011; Meyer et al. 2012). Regarding HIIE use in patients with cardiovascular risk and particularly with cardiac diseases, acute physiological responses (i.e. at cardiac, pulmonary, vascular and/or skeletal muscles levels) during different HIIE protocols as well as patient's safety, tolerance and comfort should be tested before their implementation into training programs (Guiraud et al. 2010, 2011; Meyer et al. 2012). A consistent number of studies performed previously on physiological responses during different HIIE protocols in cardiac patients are available, including those of Meyer et al. in the late 1990s (Meyer et al. 1996). Their HIIE protocol used was 30 s of cycling at 50% of maximal short-time exercise capacity (MSEC) alternating with 60 s at 10 W (Meyer et al. 1996). However, the questionable safety of the steep ramp test that has never been widely implemented in cardiac rehabilitation is a significant limitation of these studies. We have therefore developed an optimized HIIE protocol for stable patients with coronary heart disease and heart failure that consists of repeated short bouts (15 or 30 s) of exercise at 100% of peak power output interspersed with passive recovery intervals of equal duration (Guiraud et al. 2010; Meyer et al. 2012). Relative to longer intervals with active recovery, short 15–30 s exercise/recovery intervals with passive recovery were associated with a longer total exercise time, similar time spent near , a lower rating of perceived exertion, better patient comfort and a higher likelihood of completing the prescribed exercise sessions (Guiraud et al. 2010; Meyer et al. 2012). Furthermore, we also showed that compared with MICE, this optimized HIIE protocol is not only an efficient exercise modality, but also safe, and does not induce significant arrhythmias, myocardial injury in stable coronary and heart failure patients (Guiraud et al. 2011). Since September 2009, this optimized HIIE protocol has been incorporated into our clinical program in our centre, addressed to obese and coronary patients. We have showed that a 9 month lifestyle intervention using this optimized HIIE was superior to MICE to improved body composition, abdominal obesity, cardiometabolic profile, cardiovascular risk, metabolic syndrome prevalence, maximal exercise capacity and muscular endurance in viscerally obese subjects (Gremeaux et al. 2012). Optimized HIIE performed twice a week appeared feasible, safe and time-efficient in this obese population. In conclusion, validated models of HIIE specially addressed to patients with CV risks and/or cardiac diseases are available in the literature and can also be used in future exercise training research and/or clinical studies.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,008 | 0,048 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,003 | 0,003 |
| Bibliométrie | 0,002 | 0,001 |
| Études des sciences et des technologies | 0,002 | 0,004 |
| Communication savante | 0,004 | 0,006 |
| Science ouverte | 0,006 | 0,003 |
| Intégrité de la recherche | 0,037 | 0,046 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,006 | 0,011 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».