Characterization of the deflections of a catheter steered using a magnetic resonance imaging system
Notice bibliographique
Résumé
PURPOSE: The authors quantify the deflections of a catheter and a guidewire in MR setting with different designs of ferromagnetic tips and a system of high gradient coils which can generate gradients, and thus forces, 20 times larger than a conventional scanner. METHODS: Different designs of catheter tips are experimentally tested in an effort to maximize the deflections. One to two ferromagnetic spheres are attached at the distal tip of the catheter (or guidewire) with different spacing between the spheres. The effect of dipole-dipole interaction on the steering of the catheter is studied through experimentation and theoretical modeling. The effect of using many spheres on the artefact generated in fast imaging sequences is also investigated. RESULTS: A catheter and a guidewire are successfully steered by applying magnetic gradients inside a magnetic resonance scanner. More ferromagnetic material allows for larger magnetic forces, however, the use of two ferromagnetic spheres introduces undesired dipole-dipole interactions. Two ferromagnetic spheres generate a single larger artefact as they are close together. CONCLUSIONS: By varying the distance between the two ferromagnetic spheres, a balance can be struck between the need to minimize the size of the tip and the undesirable dipole-dipole interaction.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».