Notice bibliographique
Résumé
Dialysate leakage represents a major noninfectious complication of peritoneal dialysis (PD). An exit-site leak refers to the appearance of any moisture around the PD catheter identified as dialysate; however, the spectrum of dialysate leaks also includes any dialysate loss from the peritoneal cavity other than via the lumen of the catheter. The incidence of dialysate leakage is somewhat more than 5% in continuous ambulatory peritoneal dialysis (CAPD) patients, but this percentage probably underestimates the number of early leaks. The incidence of hydrothorax or pleural leak as a complication of PD remains unclear. Factors identified as potentially related to dialysate leakage are those related to the technique of PD catheter insertion, the way PD is initiated, and weakness of the abdominal wall. The pediatric literature tends to favor Tenckhoff catheters over other catheters as being superior with respect to dialysate leakage, but no consensus on catheter choice exists for adults in this regard. An association has been found between early leaks (< or =30 days) and immediate CAPD initiation and perhaps median catheter insertion. Risk factors contributing to abdominal weakness appear to predispose mostly to late leaks; one or more of them can generally be identified in the majority of patients. Early leakage most often manifests as a pericatheter leak. Late leaks may present more subtly with subcutaneous swelling and edema, weight gain, peripheral or genital edema, and apparent ultrafiltration failure. Dyspnea is the first clinical clue to the diagnosis of a pleural leak. Late leaks tend to develop during the first year of CAPD. The most widely used approach to determine the exact site of the leakage is with computed tomography after infusion of 2 L of dialysis fluid containing radiocontrast material. Treatments for dialysate leaks include surgical repair, temporary transfer to hemodialysis, lower dialysate volumes, and PD with a cycler. Recent recommendation propose a standard approach to the treatment of early and late dialysate leaks: 1-2 weeks of rest from CAPD, and surgery if recurrence. Surgical repair has been strongly suggested for leakage causing genital swelling. Delaying CAPD for 14 days after catheter insertion may prevent early leakage. Initiating CAPD with low dialysate volume has also been recommended as a good practice measure. Although peritonitis and exit-site infections are the most frequent causes of technical failure in peritoneal dialysis (PD), dialysate leaks represent one of the major noninfectious complications of PD. In some instances, dialysate leakage may lead to discontinuation of the technique (1). Despite its importance, the incidence, risk factors, management, and outcome of dialysate leakage are poorly characterized in the literature. We will review the limited available information on this topic in the next few sections.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,001 |
| Bibliométrie | 0,001 | 0,003 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».