SSR alleviation by STATCOM in induction generator based wind farm connected to series compensated line
Notice bibliographique
Résumé
In this paper, a STATCOM with voltage controller is proposed to mitigate the potential of SSR in a series compensated IG based wind farm. Detailed eigenvalue analysis is performed to demonstrate that Induction Generator effect SSR is successfully alleviated by STATCOM. The results are validated through electromagnetic transient simulation with PSCAD/EMTDC. The impacts of symmetrical fault at different locations and collector cables are investigated and the effectiveness of the proposed STATCOM controller is illustrated. It is shown that a three phase fault close to the wind farm may cause severe oscillations in the PCC voltage, electromagnetic torque and shaft torque of the wind turbine generator. To examine this situation, an equivalent circuit analysis is presented, which predicts the threshold resonant speeds within which the wind turbine becomes unstable. The study is extended to other commercially available induction generators, which also shows the potential for SSR even at realistic levels of series compensation levels, and the capability of the proposed STATCOM controller to obviate its occurrence.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».